Mass independent bias in W isotopes in MC-ICP-MS instruments

نویسندگان

  • Naoki Shirai
  • Munir Humayun
چکیده

The determination of natural mass independent isotope variations by precise isotopic measurements of elements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) requires a detailed understanding of the instrumental mass bias. Until recently, the instrumental mass bias in MC-ICP-MS analysis was considered to be entirely mass dependent, most often corrected by an exponential law. Here, we report evidence of an odd–even isotope separation in the tungsten isotopic analysis of the W isotope standard NIST SRM 3163, that is specific to the type of cones used. We also found that mass independent isotope fractionation is a ubiquitous effect in W isotope data reported on NIST SRM 3163 from other laboratories. Nuclear volume isotope effects do not provide an adequate description of this mass bias, unlike for recent reports on Nd isotopes, but a process of odd–even isotope separation is required that may occur in the expansion plume in the interface region of the ICP ion source. Newly available Jet sampler cones combined with X-skimmer cones diminish the odd–even isotope separation, while reducing the mass dependent bias by about half which is corrected adequately with application of the generalized power law. The mass independent effect observed in W is possibly related to its high first ionization potential (FIP, 7.86 eV), implying that other elements with FIP $ 8 eV may also exhibit mass independent instrumental bias in MC-ICP-MS analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Review of Mg Isotope Analytical Methods by MC-ICP-MS

Application of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has led to big breakthrough of analytical methods for metal stable isotopes, resulting in rapid progresses in non-traditional stable isotope geochemistry. As a new geological tracer, Mg isotopes have been widely applied in studies of almost all important disciplines of geochemistry. High precision Mg isotope...

متن کامل

The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC,...

متن کامل

Laser Ablation ICP-MS: particle size-dependent isotopic fractionation of copper in laser-generated aerosols

Laser induced isotopic fractionation Previous studies of laser ablation (LA) MC-ICP-MS analysis of Cu metal and sulphides showed reduced Cu/Cu ratios compared to solution nebulisation MC-ICP-MS of the same samples [1]. The fractionation of about 30ε (parts per 10,000) was reproduced repeatedly and observed, to a smaller degree, for Ag and Sb also. This deviation, which was attributed largely to...

متن کامل

Magnesium isotopic composition of igneous rock standards measured by MC-ICP-MS

Keyword: Mg isotopes Igneous rock standards MC-ICP-MS To provide inter-lab comparison for high-precision Mg isotope analysis, Mg isotope compositions (expressed as δMg relative to DSM-3) for commercially accessible peridotite, basalt, andesite, and granite geostandards have been measured by multi-collector inductively coupled mass-spectrometry (Nu-Plasma) using sample-standard bracketing method...

متن کامل

Strontium isotope ratios (87Sr/86Sr) of tooth enamel: a comparison of solution and laser ablation multicollector inductively coupled plasma mass spectrometry methods.

Strontium isotope ratios (87Sr/86Sr) in tooth enamel provide a means to investigate migration and landscape use in humans and other animals. Established methods for measuring (87)Sr/(86)Sr in teeth use bulk sampling (5-20 mg) and labor-intensive elemental purification procedures before analysis by either thermal ionization mass spectrometry (TIMS) or multicollector inductively coupled plasma ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011