Introduction Unstable intertrochanteric hip fractures can be difficult surgical challenges. Screw and side plate devices reliably stabilize stable fracture patterns [1,2], but unstable fractures require a mechanically optimized device and better implant purchase in the femoral head. These fractures have been more prone to implant failure with standard devices [3, 4]. The trochanteric femoral nail (TFN) is a helical blade device which has fins that compact the cancellous bone as it is inserted into bone and may provide improved fracture stabilization characteristics [5, 6]. A retrospective study of 273 patients with intertrochanteric hip fractures who were treated with a TFN was conducted at two institutions between 2001 and 2005. Patients underwent closed fracture reduction using traction and manipulation techniques. When the reduction was unacceptable as determined by the surgeon, adjunctive percutaneous reduction techniques were utilized. Implants were placed percutaneously, and compression of the fracture was performed in the majority of fractures. Precise measurement of movement of the blade within the femoral head and the nail was performed on all radiographs according to a previously described technique (Fig 1) [6]. The amount of telescoping was then measured as the lateral prominence of the blade lateral to the edge of the nail. X-ray measurements were made immediately postoperatively, at six weeks postoperatively, and at subsequent follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of trochanteric fractures with the PFNA (proximal femoral nail antirotation) nail system - report of early results.

Currently, intramedullary devices are widely used for the treatment of trochanteric femoral fractures. A new device designed by AO/ASIF, the PFNA (proximal femoral nail antirotation), represents a unique intramedullary nail system for improved management, particularly in the elderly. The aim of the present study was to analyze the results of treatment with PFNA in 50 patients with trochanteric ...

متن کامل

Proximal femoral nail for treatment of trochanteric femoral fractures.

PURPOSE To report outcomes of 87 consecutive patients treated with a proximal femoral nail (PFN) for trochanteric femoral fractures. METHODS 17 men and 70 women aged 58 to 95 (mean, 85) years with trochanteric femoral fractures underwent PFN fixation using an intramedullary nail, a lag screw, and a hip pin. Fractures were classified according to the AO system; the most common fracture type wa...

متن کامل

Subtrochanteric Femoral Fracture during Trochanteric Nailing for the Treatment of Femoral Shaft Fracture

We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminu...

متن کامل

Our experience of management of sub trochanteric fractures of femur by proximal femoral nail

The sub trochanteric zone of the femur is the area extending up till 5 cm distally from the inferior border of the lesser trochanter or the junction of the proximal third and middle third of the femoral shaft. Fracture patterns presenting major displacement in this area are considered sub trochanteric fractures despite their proximal or distal extension. 1 High biomechanical stress concentratio...

متن کامل

Cutout of proximal femoral nail antirotation resulting from blocking of the gliding mechanism during fracture collapse.

The proximal femoral nail antirotation had been successful in treating unstable trochanteric fractures. Previous studies have shown technical problems such as unsatisfactory fracture reduction, poor insertion technique, and poor blade position leading to complications such as cutout. We present a case of proximal femoral nail antirotation cutout resulting from the blocking of the gliding mechan...

متن کامل

Comparison of the Sliding and Femoral Head Rotation among Three Different Femoral Head Fixation Devices for Trochanteric Fractures

BACKGROUND Recently, various femoral head fixation devices (HFDs) for trochanteric fractures have become available. However, there are some cases in which femoral head rotation with excessive sliding of the HFD is observed and it is often followed by cutout. The purpose of this study is to compare the ability of the three types of HFDs to prevent femoral head rotation. METHODS Between July 20...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007