OBJECTIVES We evaluated the impact of the everolimus-eluting stent (EES) on the frequency of stent thrombosis (ST), target vessel revascularization (TVR), myocardial infarction (MI), and cardiac death in randomized controlled trials comparing the EES to non-everolimus-eluting drug-eluting stents (EE-DES). BACKGROUND Whether or not the unique properties of the EES translate into reductions in ST remains unknown. METHODS We searched MEDLINE, Scopus, the Cochrane Library, and Internet sources for articles comparing outcomes between EES and non-EE-DES without language or date restriction. Randomized controlled trials reporting the frequency of ST were included. Variables relating to patient and study characteristics and clinical endpoints were extracted. RESULTS We identified 13 randomized trials (n = 17,101) with a weighted mean follow-up of 21.7 months. Compared with non-EE-DES, the EES significantly reduced ST (relative risk [RR]: 0.55; 95% confidence interval [CI]: 0.38 to 0.78; p = 0.001), TVR (RR: 0.77; 95% CI: 0.64 to 0.92; p = 0.004), and MI (RR: 0.78; 95% CI: 0.64 to 0.96; p = 0.02). There was no difference in cardiac mortality between the groups (RR: 0.92; 95% CI: 0.74 to 1.16; p = 0.38). The treatment effect was consistent by different follow-up times and duration of clopidogrel use. The treatment effects increased with higher baseline risks of the respective control groups with the strongest correlation observed for ST (R(2) = 0.89, p < 0.001). CONCLUSIONS Intracoronary implantation of the EES is associated with highly significant reductions in ST with concordant reductions in TVR and MI compared to non-EE-DES. Whether these effects apply to different patient subgroups and DES types merits further investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Everolimus-Eluting versus Paclitaxel-Eluting Stents in Percutaneous Coronary Intervention: Meta-Analysis of Randomized Trials

Background. Individual randomized trials have suggested that everolimus-eluting stents may have improved clinical outcomes compared to paclitaxel-eluting stents, but individual trials are underpowered to examine outcomes such as mortality and very late stent thrombosis. Methods. Medline, Cochrane, and conference proceedings were searched for randomized trials comparing everolimus versus paclita...

متن کامل

Efficacy of various percutaneous interventions for in-stent restenosis: comprehensive network meta-analysis of randomized controlled trials.

BACKGROUND In-stent restenosis (ISR) remains a difficult problem in interventional cardiology. The relative efficacy and safety of available interventions is not clear. We aimed to perform a network meta-analysis using both direct evidence and indirect evidence to compare all available interventions. METHODS AND RESULTS We systematically searched electronic databases for randomized trials com...

متن کامل

Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents: A Meta-Analysis of Randomized Trials.

BACKGROUND Data regarding the long-term efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds (BVS) compared with everolimus-eluting stents are limited. This meta-analysis aimed to compare the long-term outcomes with both devices. METHODS AND RESULTS Randomized trials reporting clinical outcomes beyond 1 year and comparing BVS with everolimus-eluting stents were included....

متن کامل

Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis

OBJECTIVES To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. DESIGN Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for ...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 58 15  شماره 

صفحات  -