Compatibility of Spatially Coded Apertures with a Miniature Mattauch-Herzog Mass Spectrograph.
نویسندگان
چکیده
In order to minimize losses in signal intensity often present in mass spectrometry miniaturization efforts, we recently applied the principles of spatially coded apertures to magnetic sector mass spectrometry, thereby achieving increases in signal intensity of greater than 10× with no loss in mass resolution Chen et al. (J. Am. Soc. Mass Spectrom. 26, 1633-1640, 2015), Russell et al. (J. Am. Soc. Mass Spectrom. 26, 248-256, 2015). In this work, we simulate theoretical compatibility and demonstrate preliminary experimental compatibility of the Mattauch-Herzog mass spectrograph geometry with spatial coding. For the simulation-based theoretical assessment, COMSOL Multiphysics finite element solvers were used to simulate electric and magnetic fields, and a custom particle tracing routine was written in C# that allowed for calculations of more than 15 million particle trajectory time steps per second. Preliminary experimental results demonstrating compatibility of spatial coding with the Mattauch-Herzog geometry were obtained using a commercial miniature mass spectrograph from OI Analytical/Xylem.
منابع مشابه
Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source.
A Mattauch-Herzog geometry mass spectrograph (MHMS) has been equipped with a novel array detector, the focal plane camera (FPC). The FPC consists of an array of gold Faraday cups, each coupled to its own integrator, with interrogation of the integrators performed by a multiplexer. The initial coupling of this instrument with a pin-type glow discharge source has provided limits of detection in t...
متن کاملMattauch-Herzog Type Mass Spectrograph with a Two Stage Electrostatic Field
It is very complicated to calculate the secondorder aberrations of complex analyser systems and mistakes are liable to be made. Even if the matrix method is used the tediousness of the calculation is not altered. The usefulness of the matrix representation comes from the fact that the over-all transfer matrix of the total system is easily written as a product of the transfer matrices of various...
متن کاملA Modified Hybrid MoM-Modal Method for Shielding Effectiveness Evaluation of Rectangular Enclosures with Multiple Apertures
A new hybrid modal-moment method is proposed to calculate fields penetrated through small apertures on rectangular metallic enclosures. First, the method of moments is used to numerically solve the governing electric field integral equation for the equivalent two-dimensional surface-current distributions on the surface of metallic enclosure including any number of rectangular apertures of arbit...
متن کاملTwo-dimensional aperture coding for magnetic sector mass spectrometry.
In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy, both one-dimensional (1D) and two-dimensional (2D) aperture coding have been used for many yea...
متن کاملAn introduction to ion optics for the mass spectrograph.
A mass spectrograph is an instrument that separates and simultaneously focuses ions, along a focal plane, of different mass/charge ratios that are diverging in direction and that have a variable velocity. With these instruments and a spatially sensitive ion detector, simultaneous detection can be employed, which has been shown to improve precision and throughput (as compared to a mass spectrome...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society for Mass Spectrometry
دوره 27 4 شماره
صفحات -
تاریخ انتشار 2016