Cardiac Magnetization Transfer Imaging Using SSFP at 3T

نویسندگان

  • O. M. Weber
  • P. Speier
  • K. Scheffler
  • O. Bieri
چکیده

Introduction: It has been shown recently that the balanced steady-state free-precession (bSSFP) cine sequence, as it is used routinely for the assessment of myocardial function, shows effects of magnetization transfer (MT). These effects were successfully exploited at 1.5 Tesla [1] and at 3 T [2], offering a novel technique for myocardial tissue characterization, e.g. in acute myocardial infarct. However, SSFP at 3 T poses considerable difficulties due to increased susceptibility to off-resonance banding artefacts and limitations in flip angle as mandated by specific absorption rate (SAR) regulations. On the other hand, increased SNR and/or improved spatial resolution achievable at 3 T promise increased diagnostic value compared to 1.5 T. In this work we explored cardiac MT imaging at 3 T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Magnetization Transfer Ratio Measurements at 3T Using Multiple-Acquisition Balanced SSFP

Introduction. Magnetization transfer (MT) has become an important tool to study various tissue abnormalities, such as demyelination in brain white matter [1]. Recently, it has been shown that fast MT scans based on balanced steady-state free precession (bSSFP) with RF pulse modification achieve high SNR and high reproducibility at 1.5T [2]. At 3T, combination of multiple, phase-cycled, bSSFP sc...

متن کامل

Myocardial diffusion tensor imaging using diffusion-prepared SSFP

Background Diffusion tensor imaging of the myocardium is challenging due to the large bulk motion of the heart relative to the distance water diffuses. One solution is to use diffusion gradients on two consecutive heartbeats, with EPI to readout the stimulated echo [1]. The technique has not been widely adopted, primarily due to the long imaging times required to overcome the low SNR of the tec...

متن کامل

Whole heart magnetization-prepared steady-state free precession coronary vein MRI.

PURPOSE To compare two coronary vein imaging techniques using whole-heart balanced steady-state free precession (SSFP) and a targeted double-oblique spoiled gradient-echo (GRE) sequences in combination with magnetization transfer (MT) preparation sequence for tissue contrast improvement. MATERIALS AND METHODS Nine healthy subjects were imaged with the proposed technique. The results are compa...

متن کامل

Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: initial results.

BACKGROUND The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS Eight healthy volunteers (mean age 29 years) and eight patients...

متن کامل

Robust and fast SSFP for the evaluation of LV function at 3T

Background 3T MRI is advantageous to CMR as it offers higher SNR and better T1 contrast. Its slow clinical adoption is partly due to the lack of robustness in SSFP cine imaging [1]. Banding artifact in SSFP caused by main field inhomogeneity is common at 3T. Wideband SSFP [2] or prescans (shimming, frequency scout, etc.) are needed to avoid/ reduce the artifact, increasing patient scan time. We...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008