Dynamic range requirements in digital mammography.
نویسندگان
چکیده
The dynamic range and the number of gray levels, gamma s, required for digital mammography has been evaluated using an energy transport model. The effects of molybdenum (Mo) and tungsten (W) target spectra and the energy-dependent attenuation by elemental filters, breast tissue, and a phosphor screen were included in the model. For detectors with ideal optical coupling and no inherent detector noise, 3,100 gray levels are discernable (requiring 12 bits per pixel), assuming a 40 kVp, W target spectrum (1.0 mm A1 filtration), a mean glandular dose to a 5 cm thick breast of 0.6 mGy, and an ideal observer with a 5 mm diam viewing aperture. The effects of inherent detector noise and realistic coupling efficiency on gamma s were also examined. For the 40 kVp, W spectrum, a detector with total coupling efficiency of 16 electrons (e-) per x-ray interaction and a dynamic range of 3000 (maximum carrier signal of 1.93 x 10(5) e-/pixel and inherent detector noise of 64 e- pixel) would decrease the number of gray levels that could be resolved by only 2% compared to a detector with ideal coupling and no inherent noise. A detector with a total coupling efficiency of 2.0 electrons per x-ray interaction and a dynamic range of 240 (maximum carrier signal 2.41 x 10(4) e-/pixel and inherent detector noise of 100 e-/pixel) would reduce the number of gray levels by 26% for the 40 kVp spectrum. On the basis of dynamic range, W spectra are preferable for digital mammography, since Mo spectra yielding the same signal-to-noise ratio require a detector with dynamic range twice as large, and with a 30% greater saturation signal. When no scatter rejection method is used, scattered radiation over a 254 cm2 imaging field reduces the number of discernable gray levels by 23% for a 5 cm thick breast and 34% for an 8 cm thick breast.
منابع مشابه
Detectors for digital mammography
Introduction Mammography is the most technically demanding radiographic modality, requiring high spatial resolution, excellent low contrast discrimination, and wide dynamic range. The development of dedicated mammography systems [1] in the mid-1960s and the refinements in film-screen technology over its long evolution [2,3] were of critical importance in establishing the benefits of mammography...
متن کاملDetectors for Digital Mammography 2
The X-ray detector is the heart of a digital mammography system. Its improved characteristics of dynamic range and signal-to-noise ratio provide inherent advantages over screen-fi lm technology. Detector technologies used for digital mammography can be distinguished by the acquisition geometry into scanning or full-fi eld detectors, by energy conversion mechanism into phosphor-based and nonphos...
متن کاملBreast dose in conventional and digital mamography
Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography fo...
متن کاملDigital mammography creates new opportunities in cancer detection
Digital offers clear logistical advantages, such as the ability to integrate mammography images and reports with the rest of the digital radiology enterprise. And all major trials completed to date have concluded that clinically, digital is at least equivalent to, if not statistically better than, screen-film. With the high spatial resolution so critical for detecting masses and microcalcificat...
متن کاملPatient Dose in Digital versus Conventional Mammography
Abstract. Breast imaging techniques have received renewed attention as a proved means for earlier detection and diagnosis of breast cancer. Due to the extremely high image quality requirements in mammography, all aspects of the imaging process must be optimised. With this purpose new imaging systems have been incorporated. The aim of this paper is to present results of patient dose comparison i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 20 6 شماره
صفحات -
تاریخ انتشار 1993