Application of a low impedance contactless conductometric detector for the determination of inorganic cations in capillary monolithic column chromatography.
نویسندگان
چکیده
Poly(glycidyl methacrylate) cation exchange monolithic column was prepared in fused-silica capillaries of 320 μm i.d. by thermally initiated radical polymerization and utilized in capillary ion chromatography. With 15 mM methanesulfonic acid as the mobile phase, the separations of a mixture of inorganic cations (Li(+), Na(+), NH(4)(+), K(+)) was tested by using a capacitively coupled contactless conductivity detector (C(4)D) and a low impedance C(4)D (LIC(4)D). The LIC(4)D is the series combination of a C(4)D and a quartz crystal resonator. At the resonant frequency of the series combination, the capacitor impedance from capillary wall was offset by the inductance impedance from the quartz crystal resonator. A minimum impedance was obtained in the impedance-frequency curve of the combination. The responses of the C(4)D and LIC(4)D were analyzed based on an equivalent circuit model. It was shown that the sensitivity of the C(4)D to the change in analyte concentration is rather poor due to the high ratio of the impedance from the capillary wall capacitor to the solution impedance. The LIC(4)D has the similar sensitivity as a contact conductivity detector but a much smaller cell volume. The on-column detection model was realized by LiC(4)D without preparation of optical detection window in monolithic column.
منابع مشابه
Use of contactless conductivity detection for non-invasive characterisation of monolithic stationary-phase coatings for application in capillary ion chromatography.
A capacitively-coupled contactless conductivity detector (C4D) has been utilised as an on-capillary detector within a capillary ion chromatograph, incorporating a reversed-phase monolithic silica capillary column semi-permanently modified with a suitable ionic surfactant. The monolithic capillary column (150 x 0.1 mm i.d.) was modified using sodium dioctyl sulfosuccinate (DOSS), an anionic surf...
متن کاملDetermination of anions using monolithic capillary column ion chromatography with end-to-end differential contactless conductometric detectors under resonance approach.
An end-to-end differential measurement approach with capacitively coupled contactless conductivity detection (C(4)D) was applied to anion-exchange monolithic capillary column ion chromatography. The column was prepared by thermally initiated radical polymerization of poly(glycidyl methacrylate) in a fused-silica capillary of 320 μm i.d. and modified by quaternary ammonium latex surface coating....
متن کاملCapillary electrochromatography with contactless conductivity detection for the determination of some inorganic and organic cations using monolithic octadecylsilica columns.
A fast separation of alkali and alkaline earth metal cations and ammonium was carried out by capillary electrochromatography on monolithic octadecylsilica columns of 15 cm length and 100 microm inner diameter using water/methanol mixtures containing acetic acid as mobile phase. On-column contactless conductivity detection was used for quantification of these non-UV-absorbing species. The method...
متن کاملContactless conductivity detector for microchip capillary electrophoresis.
A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation chann...
متن کاملSimultaneous determination of inorganic cations by capillary ion chromatography with a non-suppressed contactless conductivity detector.
A non-suppressed capillary ion chromatographic method with a laboratory-made packed cation-exchange column (100 mm × 0.32 mm i.d.) was developed for the separation and simultaneous determination of five common inorganic cations (sodium, ammonium, potassium, magnesium and calcium). Cation exchangers were prepared by the reaction of the hydroxyl group on the surface of diol-group bonded silica ge...