Robust analysis of short echo time (1)H MRSI of human brain.
نویسندگان
چکیده
Short echo time proton MR Spectroscopic Imaging (MRSI) suffers from low signal-to-noise ratio (SNR), limiting accuracy to estimate metabolite intensities. A method to coherently sum spectra in a region of interest of the human brain by appropriate peak alignment was developed to yield a mean spectrum with increased SNR. Furthermore, principal component (PC) spectra were calculated to estimate the variance of the mean spectrum. The mean or alternatively the first PC (PC(1)) spectrum from the same region can be used for quantitation of peak areas of metabolites in the human brain at increased SNR. Monte Carlo simulations showed that both mean and PC(1) spectra were more accurate in estimating regional metabolite concentrations than solutions that regress individual spectra against the tissue compositions of MRSI voxels. Back-to-back MRSI studies on 10 healthy volunteers showed that mean spectra markedly improved reliability of brain metabolite measurements, most notably for myo-inositol, as compared to regression methods.
منابع مشابه
Fast MR Spectroscopic Imaging
MR spectroscopic imaging (MRSI) has become widely available as a research tool for mapping tissue metabolic status. Clinical research applications have been limited by intrinsically low sensitivity and by time-consuming phase encoding techniques that are used with conventional MRSI. The long encoding times limit volume coverage, introduce motion sensitivity and tax patient tolerance. The increa...
متن کاملFast 3D H Spectroscopic Imaging of the Human Brain at 3 Tesla using “spectroscopic Missing Pulse – SSFP” with 3D Spatial Selection
C. Schuster, W. Dreher, D. Leibfritz FB 2 (Chemistry), University of Bremen, Bremen, Germany, Center of Advanced Imaging (CAI), Bremen, Germany Introduction Over the past years several methods for fast 3D H MR spectroscopic imaging (MRSI) derived from corresponding fast MRI methods have been proposed to map the distribution of human brain metabolites. Besides echo planar MRSI and spiral MRSI [1...
متن کاملMeasurement of human brain temperature changes during cooling
Introduction Therapeutic brain hypothermia is used with increasing frequency as a tool to mitigate neurologic injury [1]. It has been shown that moderate cooling of the brain after hypoxia-ischemia can reduce damage and improve functional outcome [2, 3]. Recently a new method for selective brain cooling was described and prototype device was tested on the pigs [4, 5]. Brain temperature decreasi...
متن کاملUsing Spatial Prior Knowledge in the Spectral Fitting of Magnetic Resonance Spectroscopic Images
We propose a Bayesian smoothness prior in the spectral fitting of magnetic resonance spectroscopic images which can be used in addition to commonly employed prior knowledge. By combining a frequency-domain model for the free induction decay with a Gaussian Markov random field prior, a new optimization objective is derived that encourages smooth parameter maps. Using a particular parametrization...
متن کاملHigh-resolution 1 H-MRSI of the brain using short-TE SPICE.
PURPOSE To improve signal-to-noise ratio (SNR) for high-resolution spectroscopic imaging using a subspace-based technique known as SPectroscopic Imaging by exploiting spatiospectral CorrElation (SPICE). METHODS The proposed method is based on a union-of-subspaces model of MRSI signals, which exploits the partial separability properties of water, lipid, baseline and metabolite signals. Enabled...
متن کاملذخیره در منابع من