A 6.7μW CMOS Bioamplifier for Active Electrode with DC Rejection

نویسندگان

  • Shi Huang
  • Jinyong Zhang
  • Lei Wang
چکیده

Since the fabrication of active electrodes has been reported and their beneficial effects scientifically confirmed, we present a CMOS bioelectric amplifier with DC rejection designed for active electrode in this paper. Analysis, design and post simulation results will be described in detail. The amplifier operating at ±0.9V supply voltage has a mid-band gain of 40dB with ±300mV dc offset rejection and has a power consumption of 6.7μW. The bandwidth extends from a low-frequency cutoff of 7.9mHz to a high-frequency cutoff of 2.1kHz which is suitable for ECG signals. This proposed amplifier has an input-referred noise of 5.9μVrms. This amplifier is under fabrication in 0.18μm 1P6M CMOS Process. Keywords—active electrode; CMOS; bioelectric amplifier; DC rejection

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A low-power, low-noise CMOS amplifier for neural recording applications

There is a need among scientists and clinicians for low-noise low-power biosignal amplifiers capable of amplifying signals in the millihertz-to-kilohertz range while rejecting large dc offsets generated at the electrode–tissue interface. The advent of fully implantable multielectrode arrays has created the need for fully integrated micropower amplifiers. We designed and tested a novel bioamplif...

متن کامل

Design of low-offset low-power CMOS amplifier for biosensor application

A compacted and low-offset low-power CMOS amplifier for biosensor application is presented in this paper. It includes a low offset Op-Amp and a high precision current reference. With a novel continuoustime DC offset rejection scheme, the IC achieves lower offset voltage and lower power consumption compared to previous designs. This configuration rejects large DC offset and drift that exist at t...

متن کامل

Fully Integrated Biopotential Acquisition Analog Front-End IC

A biopotential acquisition analog front-end (AFE) integrated circuit (IC) is presented. The biopotential AFE includes a capacitively coupled chopper instrumentation amplifier (CCIA) to achieve low input referred noise (IRN) and to block unwanted DC potential signals. A DC servo loop (DSL) is designed to minimize the offset voltage in the chopper amplifier and low frequency respiration artifacts...

متن کامل

A 3 - V Cmos Optical Preamplifier with Dc Photocurrent Rejection

This paper describes a CMOS optical preamplifier suitable for free-space, infrared wireless communications. The design is differential for improved power supply noise rejection, and an active cancellation scheme is used for eliminating dc photocurrents that are generated by ambient light. Making use of a 0.35-µm CMOS process, the preamplifier provides a transimpedance gain of 20 kΩ over a bandw...

متن کامل

Design of a Cmos Bandgap Reference with Lowtemperature Coefficient and High Power Supply Rejection Performance

A high precision temperature compensated CMOS bandgap reference is presented. The proposed circuit employs current-mode architecture that improves the temperature stability of the output reference voltage as well as the power supply rejection when compared to the conventional voltage-mode bandgap referenc. Using only first order compensation the new architecture can generate an output reference...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013