Non-invasive estimation of venous admixture: validation of a new formula.
نویسندگان
چکیده
We have developed a computer program that estimates venous admixture (intra-pulmonary shunt) from four measurements: haemoglobin concentration, end-tidal carbon dioxide tension (PE'CO2), fractional inspired oxygen concentration (FIO2) and pulse oximetry (SpO2). The formula was tested on patients in an intensive therapy unit by using it to estimate shunt while it was measured simultaneously by a standard, invasive method. A total of 101 measurements were made in 29 patients. After correcting the systematic errors in the assumed differences between PE'CO2 and arterial PCO2, and between SpO2 and co-oximetrically measured SaO2, and correcting for a trend in the arteriovenous oxygen concentration difference (C(a-v))2) with shunt, the bias of the non-invasive minus invasive shunt differences was negligible, with no significant dependence on shunt. The limits of agreement were then +/- 16% shunt overall (+/- 13% within patients). When SaO2 was used instead of SpO2, the limits were +/- 11% (+/- 8% within patients).
منابع مشابه
Estimating venous admixture using a physiological simulator.
Estimation of venous admixture in patients with impaired gas exchange allows monitoring of disease progression, efficacy of interventions and assessment of the optimal inspired oxygen fraction. A pulmonary artery catheter allows accurate measurement, although the associated risks preclude its use solely for estimation of venous admixture. Non-invasive methods require assumed values for physiolo...
متن کاملLarge-scale Inversion of Magnetic Data Using Golub-Kahan Bidiagonalization with Truncated Generalized Cross Validation for Regularization Parameter Estimation
In this paper a fast method for large-scale sparse inversion of magnetic data is considered. The L1-norm stabilizer is used to generate models with sharp and distinct interfaces. To deal with the non-linearity introduced by the L1-norm, a model-space iteratively reweighted least squares algorithm is used. The original model matrix is factorized using the Golub-Kahan bidiagonalization that proje...
متن کاملValidity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content
Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...
متن کاملStandardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study
Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...
متن کاملDischarge Estimation by using Tsallis Entropy Concept
Flow-rate measurement in rivers under different conditions is required for river management purposes including water resources planning, pollution prevention, and flood control. This study proposed a new discharge estimation method by using a mean velocity derived from a 2D velocity distribution formula based on Tsallis entropy concept. This procedure is done based on several factors which refl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 74 5 شماره
صفحات -
تاریخ انتشار 1995