INTRODUCTION To compare the cleaning effectiveness of K3 and Race NiTi rotary systems with K-Flexo file instruments during the preparation of curved canals in extracted human teeth. MATERIALS AND METHODS A total of 50 root canals of mandibular and maxillary molars with curvatures ranging between 25º and 35 º were divided in three groups of 15 each and 5 as negative control groups. Canals were prepared using a low torque control motor in two rotary groups according to manufacturer's instructions. Conventional Step back with S.S K files was the preparation technique in third group. The amount of debris and smear layer was quantified on the basis of a numerical evaluation scale. The data were statistically analyzed using Chi-Square and Likelihood Ratio tests. RESULTS In general, no significant difference in terms of amount of debris were found among three groups, only in apical zones of Race and K-Flexo file groups a significant difference was detected (P=0.041). Race rotary system left significantly less smear layer than k-Flexo file in the middle (P=0.009) and apical thirds (P=0.012), respectively. K3 significantly achieved higher scores of cleanliness than K-Flexo file in apical third only (P=0.049). No significant difference between Race and K3 rotary groups for residual debris and formed smear layer was detected. CONCLUSION Obtaining higher scores of cleanliness in various regions of the canals, crown down technique and the use of rotary instrumentation seem to be superior to conventional hand instrumentation with step back technique .No significant difference between K3 with three radial lands and Race with three cutting edges in terms of debris and smear layer formation was detected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment Dr. J. Ghoddusi*- Dr. P. Ghaziani*- Dr. Sh. Nazari** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Hamedan University of Medical Science...

متن کامل

SEM evaluation of root canal dentin morphology after Ni-Ti instrumentation.

PURPOSE The aim of this study was to compare, through scanning electron microscope (SEM), the ability of four Ni-Ti rotary instrument systems in shaping root canal walls and their ability in removing smear layer and dentin debris. METHODS Forty-six extracted single-rooted human teeth were divided into four groups and prepared to size 35 (Alpha System, FlexMaster, MFile) or 30 (NRT files). Irr...

متن کامل

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...

متن کامل

Comparative Evaluation of Smear Layer and Debris on the Canal Walls prepared with a Combination of Hand and Rotary ProTaper Technique using Scanning Electron Microscope.

INTRODUCTION The effect of smear layer and debris on the success rate of endodontic treatment has not yet been definitely determined. So the present study was aimed to evaluate the amount of smear layer and debris on the canal walls prepared with a combination of hand and rotary ProTaper technique using NaOCl and ethylenediaminetetraacetic acid (EDTA) alternately as root canal irrigants using s...

متن کامل

Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties

Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files allows the clinicians to produce the desirable tapered root canal form with a reduced tendency to canal transportation and instrument fracture. Hy...