Development and performance evaluation of a high‐speed multileaf collimator

نویسندگان

  • Xiang Zhang
  • Peiqing Ye
  • Hui Zhang
چکیده

Multileaf collimator (MLC) tracking represents a promising technique for motion management in radiotherapy. However, the conflict between limited leaf speed/acceleration and the demand for tracking fast target motion is now a prominent issue. Conventional MLCs typically have a maximum leaf speed of 3-4 cm/s and a maximum leaf acceleration of 50-70 cm/s2, which are inadequate to track fast target motion. To cope with this problem, we have recently developed a high-speed multileaf collimator (HS-MLC) prototype, which employs linear motors instead of rotary motors to drive leaves. Consequently, it inherits various benefits of linear motors, including direct drive and high dynamics. The primary aim of this paper was to introduce the development and performance evaluation of the HS-MLC. The evaluation includes Monte Carlo simulations of the basic dosimetric properties, camera-based measurements of the mechanical properties and tracking experiments for 25 sets of patient-measured motion data. The Monte Carlo simulation results show that the maximum leakage at 6MV is 1.29% and the average is 0.61%. The end-to-end leakage is 3.96% for 5 cm offset and is 1.75% for 10 cm offset. The penumbra for a standard 10 × 10 cm2 field ranges from 4.8 mm to 5.4 mm across the full range of leaf motion. The mechanical property measurements demonstrate that the maximum leaf speed is 40 cm/s, the maximum leaf acceleration is 1000 cm/s2, and the geometric accuracy can be kept within 0.5 mm. Regarding the tracking experiments for a wide range of motion patterns (fast breathing, irregular breathing, etc.), a root-mean-square error (RMSE) of less than 0.19 mm was achieved. In conclusion, the HS-MLC is able to well track fast target motion that is beyond the capability of conventional MLCs due to its superior mechanical properties. The new MLC design provides a feasible solution to make high-accuracy and high-efficiency motion management possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...

متن کامل

Dosimetric and qualitative analysis of kinetic properties of millennium 80 multileaf collimator system for dynamic intensity modulated radiotherapy treatments.

The aim of this paper is to analyze the positional accuracy, kinetic properties of the dynamic multileaf collimator (MLC) and dosimetric evaluation of fractional dose delivery for the intensity modulated radiotherapy (IMRT) for step and shoot and sliding window (dynamic) techniques of Varian multileaf collimator millennium 80. Various quality assurance tests such as accuracy in leaf positioning...

متن کامل

Design, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy

Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...

متن کامل

The Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions

Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -