Magnetic Resonance Multi-view Inverse Imaging (MV InI) for Human Brain
نویسندگان
چکیده
Dynamic MRI usually uses echo-planar imaging (EPI) [1] to achieve high temporal resolution. In brain imaging, modern MRI systems can achieve 3D spatial encoding with the whole-brain coverage using multi-slice EPI with TR of 2 s. A significant amount of time of multi-slice EPI is spent over k-space traversal. Recently, we proposed the MR inverse imaging (InI) [2] to achieve the unprecedented temporal resolution (100ms) with whole-brain coverage using simultaneous acquisitions from channels of an RF coil array. InI traded off the spatial resolution for temporal resolution in solving ill-posed inverse problem. In this study, we propose the multi-view inverse imaging (MV InI) to achieve fast 3D MR imaging without compromised spatial resolution. Specifically, MV InI acquires projection data from three orthogonal directions (x-, y-, and z-axes) and all channels of an RF coil array. All data are used simultaneously to solve the unknown 3D distribution of the magnetization. Here we present the pulse sequence and preliminary reconstruction of MV InI using a 32-channel head coil array at 3T to achieve 300 ms temporal resolution and 4 mm isotropic spatial resolution.
منابع مشابه
Dynamic magnetic resonance inverse imaging of human brain function.
MRI is widely used for noninvasive hemodynamic-based functional brain imaging. In traditional spatial encoding, however, gradient switching limits the temporal resolution, which makes it difficult to unambiguously identify possible fast nonhemodynamic changes. In this paper we propose a novel reconstruction approach, called dynamic inverse imaging (InI), that is capable of providing millisecond...
متن کاملOptimal Sampling and Reconstruction Patterns for Magnetic Resonance Inverse Imaging and MR- Encephalography
Due to the low temporal resolution of the traditional MRI acquisition techniques employed for noninvasive hemodynamic-based functional brain imaging, gradient switching hinders the unambiguous detection of possible rapid nonhemodynamic changes [1]. A method is introduced in [1], which utilizes an array of parallel receivers to measure the functional contrast and dynamic statistical parametric m...
متن کاملImproving the spatial resolution of whole-head magnetic resonance inverse imaging using partition-encoding gradient blips
Using simultaneous acquisition from multiple channels of a radio-frequency (RF) coil array, magnetic resonance inverse imaging (InI) achieves functional MRI acquisitions at a rate of 100 ms per whole-brain volume [1]. InI accelerates the scan by leaving out partition encoding steps and reconstructs images by solving under-determined inverse problems using RF coil sensitivity information. Hence,...
متن کاملMulti-projection magnetic resonance inverse imaging of the human visuomotor system
Using highly parallel radiofrequency (RF) detection, magnetic resonance inverse imaging (InI) can achieve 100 ms temporal resolution with whole brain coverage. This is achieved by trading off partition encoding steps and thus spatial resolution for a higher acquisition rate. The reduced spatial information is estimated by solving under-determined inverse problems using RF coil sensitivity infor...
متن کاملEvent-related single-shot volumetric functional magnetic resonance inverse imaging of visual processing
Developments in multi-channel radio-frequency (RF) coil array technology have enabled functional magnetic resonance imaging (fMRI) with higher degrees of spatial and temporal resolution. While modest improvement in temporal acceleration has been achieved by increasing the number of RF coils, the maximum attainable acceleration in parallel MRI acquisition is intrinsically limited only by the amo...
متن کامل