Measurements of Inter- and Intravoxel Dephasing of Trabecular Bone at 7T Field Strength using a Chemical Shift-Selective Asymmetric Spin-Echo (Chase) Sequence

نویسندگان

  • R. Krug
  • A. J. Burghardt
  • K. E. Hammond
  • S. Banerjee
  • D. A. Kelley
  • A. S. Issever
  • T. M. Link
  • S. Majumdar
چکیده

Introduction: Magnetic resonance imaging has increasingly become the method of choice to assess trabecular bone architecture in vivo non-invasively and without ionizing radiation to evaluate the progression of osteoporosis. This is commonly done by quantitative analysis of bone structural properties from high-resolution MR images. In this work, we hypothesized that measurements of interand intravoxel dephasing of the MR signal can provide information about the structural organization and topology of trabecular bone in addition to direct structural measurements. We studied these phenomenona using simulations, MR experiments at 7T and 3T as well as peripheral quantitative computed tomography (HR-pQCT) imaging. Due to differences in susceptibility between the more diamagnetic bone and the bone marrow interface, induced magnetism is generated leading to a variation of spin phases. This mechanism can be quantified as intervoxel dephasing (phase differences between the voxels) and intravoxel dephasing (T2* relaxation time measurements). Also, interand intravoxel phase measurements of trabecular bone have not yet been reported using high-field MRI (3T) and ultra high-field (UHF) MRI at 7T. In addition and in order to investigate the decay characteristics we simulated the T2* decay behavior of bone by using a magnetostatic model of trabecular bone (1). Furthermore, we measured the global magnetic field structure (B0) within the region of interest (the trabecular bone) at both 7T and 3T field strength. Theory: Trabecular structures with greater relative surface area (e.g. “rod-like”) should exhibit increased interand intravoxel dephasing whereas structures with lower relative surface area (e.g. “plate-like”) should exhibit decreased dephasing within a voxel. Intravoxel dephasing, leading to signal phase cancellation in the voxel, can be quantified by T2* relaxation measurements. Intervoxel dephasing can be characterized by the standard deviation of the phase image histogram. Material and Methods: A Chemical Shift-Selective Asymmetric Spin-Echo (Chase) pulse sequence (2) was implemented at 7T and 3T. Using this sequence, the trabecular bone microstructure of the wrist was imaged in five intact human cadaveric arm specimens at both field strengths at spatial resolutions of 937μm and 625μm and 3mm slice thickness. For measurements of intervoxel dephasing a high-pass filter was applied to the unwrapped phase images (3) and standard deviations of the phases across the voxels were computed. A global magnetic field map was derived from the phase images. Regression analysis was used to investigate correlations between phase parameters and structural and topological measurements obtained from 3D HR-pQCT scans that were acquired at an isotropic voxel size of 41 μm. Additionally, we investigated the theoretical T2* decay behavior in trabecular bone at different field strengths based on a magnetostatic model of trabecular bone that simulates the susceptibility-induced inhomogeneities in a voxel comprised partly of bone and partly of bone marrow. The signal response of the CHASE sequence was simulated by numerical solution of the Bloch equation at each effective echo time TE and a decay curve was fitted to the simulated data points.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IDEAL at 7T in Mice Using Asymmetric Spin Echo and Gradient Echo Acquisitions

An asymmetric spin echo (aSE) technique was developed to produce uniform, robust fat-water separation in mice at 7T using Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-squares estimation method (IDEAL). The aSE technique had superior image quality as compared to gradient echo IDEAL estimation. Both the spin echo and gradient echo IDEAL techniques resulted in more accura...

متن کامل

Performance of two spin-echo sequences for quantitative structure analysis of trabecular bone

Introduction: The susceptibility difference between bone and bone marrow promotes the use of spin echo-based sequences for high resolution magnetic resonance imaging (μMRI) of trabecular bone (TB) [1], particularly for B0>1.5T. At ultra high field strengths, specific absorption rate (SAR) limits for patient safety are breached by the fast large-angle spin-echo (FLASE) pulse sequence. Fast spin ...

متن کامل

Ultrashort Echo Time Imaging of Cortical Bone at 7 Tesla Field Strength

Introduction MRI at ultra-high field (UHF) strength of 7 Tesla has been increasingly used and optimized for in vivo applications over the past few years. In particular, the increased signal to noise ratio (SNR) renders this new modality very attractive for imaging soft tissues in the human body. More solid or semi-solid tissues such as trabecular and cortical bone provide little to no signal in...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Reduced SAR with BASE Sequence at 7 Tesla

Introduction: To reduce measurement time, sequences are required which either significantly reduce the repetition time or acquire several echoes within each excitation. Among those the Turbo Spin Echo (TSE) is widely used today on clinical scanners at typical field strength of 1.5T to 3T. The step towards 7T provides a significantly higher MR signal potentially allowing for decreased scan time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008