Comparison of Filtration Efficiency Measurements between TSI Model 8160 , TSI Model 3140 , and ATI 100 P Filter Test Stands

نویسنده

  • Mary E. Pierce
چکیده

The penetration result obtained on a filter test stand depends on several factors. Two of these are challenge aerosol size distribution and the particle detector used to measure the particle size and concentration. Some filter testers employ a monodisperse aerosol challenge while others use a polydisperse challenge. Some particle detectors are based on particle counting while others are based on light scattering detection. Johnson and Smith have shown that small differences in these factors can have a dramatic effect on the penetration value obtained. Other factors that affect the penetration are the fiber diameters in the filter media tested and the face velocity of the test. The goal of this study was to present a correlation between the MPPS penetration as measured by the TSI CertiTest 8160 and the penetration values obtained by the TSI model 3140. We also present a correlation of MPPS penetration with filter media face velocity that may be useful for extrapolation purposes. For the HEPA and sub-HEPA grades the 100P penetration was measured to estimate the particle size this test stand is measuring compared to the 8160. Introduction The age of high efficiency filtration began after WWI when protection of troops from poisonous gas attacks became a priority for the military. In the area of filter testing, LaMer and Sinclair developed a filter test stand using a thermally generated di-octyl-phthalate (DOP) smoke cloud to challenge the filter and optical photometers to determine aerosol concentration upstream and downstream of the filter. At that time the DOP smoke was thought to be an aerosol of monodisperse 0.30 micrometer spheres. This instrument became the basis for US MIL-STD-282 and subsequently MIL-STD-51079 and MIL-STD51068 for testing HEPA filter media and HEPA filters. Later Hinds et al determined that the hot DOP aerosol generated by the Sinclair test stand was not monodisperse, but was actually a polydisperse aerosol having a count mean diameter of 0.23 micrometers. Even so, MIL-STD-282 has remained the accepted industry standard for testing HEPA filter media. In recent years ATI has developed a cold DOP aerosol test stand, model 100P, to replace the Q-127 thermal DOP test stand. ATI reports that the cold DOP aerosol generated by the 100P has a count mean diameter of 0.22 micrometers and geometric standard deviation of 1.6. With the introduction of filter test stands based on laser particle counters and condensation particle counters combined with differential mobility particle sizers in the 1980’s, new filter efficiency test stands were developed to meet the needs of the booming electronics industry. The newer particle counter based test stands could accurately measure filter efficiencies of up to 99.999998 percent on particles ranging in size from 0.075 to 10 micrometers for laser particle counters and 0.015 to 0.40 micrometers for condensation particle counters. These test stands allowed the generation of fractional penetration curves that experimentally demonstrated Langmuir’s theory that there is a particle size for which filtration efficiency of a filter medium is minimum. Two standards that reference reporting the penetration at the most penetrating particle size (MPPS) are IEST-RP-021 and the European standard, EN1822. The CertiTest 8160 is a filtration test stand that utilizes monodisperse challenge aerosol and condensation particle counters (CPC’s) to detect the aerosol concentration upstream and downstream. This filter tester has the capability of measuring a fractional penetration curve for particle sizes in the range of 0.015 to 0.4 micrometers. The Model 3140 is a new generation of TSI 8140 tester. It is also a CPC based filtration test stand, but only provides a single penetration measurement for a fixed particle size distribution aerosol challenge.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of filter media for particle number, surface area and mass penetrations.

The National Institute for Occupational Safety and Health (NIOSH) developed a standard for respirator certification under 42 CFR Part 84, using a TSI 8130 automated filter tester with photometers. A recent study showed that photometric detection methods may not be sensitive for measuring engineered nanoparticles. Present NIOSH standards for penetration measurement are mass-based; however, the t...

متن کامل

TSI ultrasound elastography for the diagnosis of chronic allograft nephropathy in kidney transplanted patients

PURPOSE To answer the question whether the TSI (tissue strain imaging) sonoelastography technique can contribute to the diagnosis of chronic renal allograft damage. MATERIAL AND METHODS A prospective study of 112 patients between June 2010 and April 2011 was conducted to compare elastography data with biopsy results and laboratory parameters in order to determine whether any correlations exis...

متن کامل

ACRIM-gap and TSI trend issue resolved using a surface magnetic flux TSI proxy model

The ACRIM-gap (1989.5-1991.75) continuity dilemma for satellite TSI observations is resolved by bridging the satellite TSI monitoring gap between ACRIM1 and ACRIM2 results with TSI derived from Krivova’s [2007] proxy model based on variations of the surface distribution of solar magnetic flux. ‘Mixed’ versions of ACRIM and PMOD TSI composites are constructed with their composites’ original valu...

متن کامل

Relationship between thyroid stimulating hormone and thyroid stimulating immunoglobulin in Graves' hyperthyroidism.

BACKGROUND AND AIM In Graves' hyperthyroidism, suppression of serum TSH after restoration of normal serum T4 and T3 with treatment has been attributed to binding of TSH-receptor antibodies to TSH receptors in the pituitary. Accordingly, the relationship between TSH and serum thyroid stimulating immunoglobulin (TSI) was examined during follow-up of patients with Graves' hyperthyroidism. SUBJEC...

متن کامل

ارزیابی کارایی پالایش ذرات زیر میکرونی ماسک های جراحی داخلی و وارداتی

Background and Aim: Bioaerosols are one of the most important agents that cause post operating infections in hospitals. Surgical masks are recommended for prevention of bioaerosols transmition in operating rooms. This study aimed at evaluation of submicron particle filtration efficiency of domestic and imported surgical masks. Materials and Methods: In this cross sectional study, 5 types of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006