Skewed adiabatic pulses for outer volume suppression in single voxel spectroscopy

نویسندگان

  • F. Giove
  • F. Marcocci
  • F. Fasano
  • M. DiNuzzo
  • G. E. Hagberg
  • B. Maraviglia
چکیده

Commonly, the product spectroscopic sequences available on commercial scanners don’t take full advantage of the scanner hardware. At an intermediate, now widely available field of 3T, issues like chemical shift displacement and contamination by external lipids become a problem, especially because of the low γB1 and the slow prescribed gradients. In this context, detection of metabolites at low concentrations and with chemical shift near large lipid resonances (e.g. like lactate) is critical. Here we adopted an OVS suppression based on skewed asymmetric adiabatic pulses [Hwang1999], along with high performance dephasing gradients, in order to examine to what extent a substantial decrease of voxel signal contamination can be obtained on clinical scanners, without compromising water suppression efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outer Volume Suppression (OVS) for Single Voxel Spectroscopy (SVS) at 7 Tesla using interleaved B1 shim settings

Introduction High-field magnetic resonance spectroscopy (MRS) has the potential to provide enhanced neurochemical information based on increased sensitivity and higher spectral resolution. However, problems arising in high-field magnetic resonance imaging (MRI), such as more pronounced B0 and B1 inhomogeneities, may decrease spectral resolution and ultimately the quantification accuracy. A mult...

متن کامل

Short-echo, single-shot, full-intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: validation in the cerebellum and brainstem.

A short echo time (TE = 24 ms) semiadiabatic localization by adiabatic selective refocusing (LASER) sequence was designed and optimized for full-intensity proton magnetic resonance spectroscopy ((1) H MRS) at 4 T. The sequence was combined with VAPOR water suppression and three-dimensional outer volume suppression for improved localization and suppression of unwanted coherences. Artifact-free, ...

متن کامل

Zoomed functional imaging in the human brain at 7 Tesla with simultaneous high spatial and high temporal resolution.

Functional neuroimaging in the human brain using noninvasive magnetic resonance methods has the potential of providing highly resolved maps of neuronal activation. Decreasing the voxel size and obtaining simultaneously high temporal resolution is a major challenge and is mainly limited by sensitivity. Here, signal-to-noise gains at high magnetic fields (7 Tesla) and an optimized surface coil se...

متن کامل

Selective resonance suppression 1H-[13C] NMR spectroscopy with asymmetric adiabatic RF pulses.

Despite obvious improvements in spectral resolution at high magnetic field, the detection of 13C labeling by 1H-[13C] NMR spectroscopy remains hampered by spectral overlap, such as in the spectral region of 1H resonances bound to C3 of glutamate (Glu) and glutamine (Gln), and C6 of N-acetylaspartate (NAA). The aim of this study was to develop, implement, and apply a novel 1H-[13C] NMR spectrosc...

متن کامل

Single- and Multi-Voxel MR-Spectroscopy Using Parallel Excitation

Introduction The use of multi-dimensional spatially-selective excitation (SSE) pulses for MR-spectroscopy (MRS) offers great potential for solving several problems generally occuring in classical volume-selective MRS with single rectangular voxels. On the one hand, the possibility of exciting arbitrarily shaped voxels, adapted to anatomical structures, can help maximizing the target-volume whil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009