Measurements of conduction times with catheter electrodes during pacing from different ventricular sites.

نویسندگان

  • A Castellanos
  • A S Agha
  • B Befeler
  • R J Myerburg
چکیده

Filtered bipolar catheter electodes, I mm apart, were used to pace and record from the high right atrium, right ventricular apex, right ventricular outflow tract, right ventricular inflow tract, middle cardiac vein, great cardiac vein, and endocardium of the left ventricular septal surface. Right ventricular apex to middle cardiac vein and the middle cardiac vein to right ventricular apex conduction intervals gave a rough estimate of anteroposterior and posteroanterior "transseptal plus free left ventricular wall" conduction times, respectively. On the other hand, the right ventricular apex to left ventricular septal surface and left ventricular septal surface to right ventricular apex intervals represented pure "transseptal" conduction times, since both sets of electrodes were in contact with the respective septal surface. During stimulation of the intermediately located right ventricular inflow tract propagation to the right ventricular apex and right ventricular outflow tract was longer than between these two sites. Moreover, conduction was almost as delayed to the right ventricular apex and right ventricular outflow tract as it was to the left ventricular septal surface. These findings were attributed to the peculiar electrophysiological behaviour of the right ventricular inflow tract muscle. Pacing from different segments of the great cardiac vein produced QRS morphologies and arrival of excitation patterns consistent with the relation between the anatomical location of this structure and the recording electrodes. However, from this study no inferences could be drawn regarding the conduction velocity or specific conduction pathways used by the stimulus in its journey from stimulating to recording areas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemapping

Pacemapping (PM) is an electrophysiologic technique designed to help locating tachycardia sources by stimulating at different endocardial sites in order to reproduce the clinical tachycardia characteristics. A recorded electrocardiogram (ECG) during the clinical tachycardia has been conventionally used as reference. Yet, endocardial activation pattern during tachycardia may be utilized as well ...

متن کامل

Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infarction.

BACKGROUND Ventricular tachycardia reentry circuits in chronic infarct scars can contain slow conduction zones, which are difficult to distinguish from bystander areas adjacent to the circuit during catheter mapping. This study developed criteria for identifying reentry circuit sites using computer simulations. These criteria then were tested during catheter mapping in humans to predict sites a...

متن کامل

New manifestations of electrophysiological remodeling of heart during experimental model of atrial fibrillation in cirrhotic rat isolated heart

Introduction: The present study is aimed to evaluate electrophysiological remodeling of atrioventricular (AV) node and ventricular conduction during experimental atrial fibrillation (AF) model in isolated heart of cirrhotic rats. Methods: Cirrhosis-induced electrophysiological remodeling was evaluated in 24 isolated retrogradely perfused rat hearts in 2 groups (control and cirrhotic). Cirrho...

متن کامل

Resolution of pace mapping stimulus site separation using body surface potentials.

BACKGROUND Several studies have related 12-lead ECG waveform during ventricular tachycardia to ECG waveform during ventricular pacing to identify ablation sites for therapy of ventricular tachycardia. QRS isopotential maps and QRS isointegral maps derived from body surface isopotential maps have also been correlated with left ventricular pacing sites with the same objective. The comparison proc...

متن کامل

Atrial excitability and conduction during rapid atrial pacing.

Using temporary atrial wire electrodes placed at selected atrial sites, rapid atrial pacing at rates of up to 368 beats/min was used to study atrial excitability and conduction in seven patients who underwent open heart surgery. The threshold for atrial pacing was found to be an exponential function of pacing rate (r = 0.55, p less than 0.01), increasing threefold when the fastest pacing rates ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1975