Whole-heart dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve: determination of volumetric myocardial ischaemic burden and coronary lesion location.
نویسندگان
چکیده
AIMS Dynamic three-dimensional-cardiac magnetic resonance (3D-CMR) perfusion proved highly diagnostic for the detection of angiographically defined coronary artery disease (CAD) and has been used to assess the efficacy of coronary stenting procedures. The present study aimed to relate significant coronary lesions as assessed by fractional flow reserve (FFR) to the volume of myocardial hypoenhancement on 3D-CMR adenosine stress perfusion imaging and to define the inter-study reproducibility of stress inducible 3D-CMR hypoperfusion. METHODS AND RESULTS A total of 120 patients with known or suspected CAD were examined in two CMR centres using 1.5 T systems. The protocol included cine imaging, 3D-CMR perfusion during adenosine infusion, and at rest followed by delayed enhancement (DE) imaging. Fractional flow reserve was recorded in epicardial coronary arteries and side branches with ≥2 mm luminal diameter and >40% severity stenosis (pathologic FFR < 0.75). Twenty-five patients underwent an identical repeat CMR examination for the determination of inter-study reproducibility of 3D-CMR perfusion deficits induced by adenosine. Three-dimensional CMR perfusion scans were visually classified as pathologic if one or more segments showed an inducible perfusion deficit in the absence of DE. Myocardial ischaemic burden (MIB) was measured by segmentation of the area of inducible hypoenhancement and normalized to left ventricular myocardial volume (MIB, %). Three-dimensional CMR perfusion resulted in a sensitivity, specificity, and diagnostic accuracy of 90, 82, and 87%, respectively. Substantial concordance was found for inter-study reproducibility [Lin's correlation coefficient: 0.98 (95% confidence interval: 0.96-0.99)]. CONCLUSION Three-dimensional CMR stress perfusion provided high diagnostic accuracy for the detection of functionally significant CAD. Myocardial ischaemic burden measurements were highly reproducible and allowed the assessment of CAD severity.
منابع مشابه
Validation of dynamic three-dimensional whole heart magnetic resonance myocardial perfusion imaging at 3.0 Tesla against fractional flow reserve for the detection of flow-limiting coronary heart disease
We demonstrate the feasibility of 3D myocardial perfusion CMR at 3 Tesla against fractional flow reserve (FFR) in 53 patients for the detection of flow-limiting coronary artery disease and show good agreement between the techniques. This technique shows excellent diagnostic sensitivity and specificity and may offer an alternative method of detecting ischaemia for the purpose of guiding revascul...
متن کاملMulticenter evaluation of dynamic three-dimensional whole-heart myocardial perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve
Background Cardiac magnetic resonance (CMR) perfusion imaging yields high diagnostic accuracy for the detection of coronary artery disease (CAD) [1]. However, standard 2D multislice CMR perfusion techniques only provide limited coverage and hence prohibit computation of myocardial ischemic burden. Recently, two single-center 3D CMR perfusion studies have proven highly diagnostic for the detecti...
متن کاملValidation of dynamic 3-dimensional whole heart magnetic resonance myocardial perfusion imaging against fractional flow reserve for the detection of significant coronary artery disease.
OBJECTIVES The goal of this study was to determine the diagnostic accuracy of dynamic 3-dimensional (3D) whole heart myocardial perfusion cardiovascular magnetic resonance (CMR) against invasively determined fractional flow reserve (FFR) and to establish the correlation between myocardium at risk defined by using the invasive Duke Jeopardy Score (DJS) and noninvasive 3D whole heart myocardial p...
متن کاملMulticenter evaluation of dynamic three-dimensional magnetic resonance myocardial perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve.
BACKGROUND First-pass myocardial perfusion cardiovascular magnetic resonance (CMR) imaging yields high diagnostic accuracy for the detection of coronary artery disease (CAD). However, standard 2D multislice CMR perfusion techniques provide only limited cardiac coverage, and hence considerable assumptions are required to assess myocardial ischemic burden. The aim of this prospective study was to...
متن کاملAdditive value of magnetic resonance coronary angiography in a comprehensive cardiac magnetic resonance stress-rest protocol for detection of functionally significant coronary artery disease: a pilot study.
BACKGROUND Cardiovascular magnetic resonance (CMR) myocardial perfusion imaging (MPI) is a state-of-the-art noninvasive modality for detection of myocardial ischemia and coronary artery disease. Magnetic resonance coronary angiography (MRCA) allows visualization of the coronary tree, but its incremental value as part of a CMR protocol including MPI and late gadolinium enhancement (LGE) is not w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 33 16 شماره
صفحات -
تاریخ انتشار 2012