Cerebral Blood Flow Determined by Saturation and Desaturation with Krypton-85: an Evaluation of the Validity of the Inert Gas; Method of Kety and Schmidt.

نویسندگان

  • N A LASSEN
  • A KLEE
چکیده

• In the original inert gas method of Kety and Schmidt the saturation of the brain with the inert gas, N,,O, is followed for 10 minutes. In a group of subjects we have studied both the saturation and the desaturation of the brain with krypton as the inert gas. The results give an experimental demonstration of a relatively small systematic error inherent in the method apparently due to differences of the uptake rate of inert gas in the various cerebral tissues. The error is discussed with particular emphasis on the use of extrapolation to infinity for the purpose of counteracting it.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Local Blood Flow with Hydrogen Gas.

• The use of inert gases was introduced for measuring cerebral blood flow by Kety and Schmidt in 1945* and has since found wide application to the brain and other regions. Nitrous oxide has been used for measuring cerebral, myocardial, and renal blood flow," while labelled krypton has been used for the same organs by other investigators." The method requires simultaneous measurement of the gas ...

متن کامل

11 Measuring Cerebral Blood Flow and Metabolism

The first well-recognized CBF studies on humans were performed by Kety and Schmidt in the 1940s using nitrous oxide (N2O) gas. The measurement of CBF was based on the principle that the rate of uptake and clearance of an inert diffusible gas is proportional to blood flow. The tissue concentration of the tracer at equilibrium must therefore be dependent on blood flow rather than diffusibility. T...

متن کامل

Human cerebral blood flow measured by two inert gas techniques. Comparison of the Kety-Schmidt method and the intra-arterial injection method.

Two inert gas methods for measurement of tissue blood flow were compared. The two methods are (1) Kety and Schmidt's inert gas saturation method, in which the tissue saturation is followed by detecting the concentration of the tracer in the venous blood leaving the organ and (2) the intraarterial radioactive inert gas injection method where the tissue washout is measured by detecting the residu...

متن کامل

A Method for the Continuous Measurement of Cerebral Blood Flow in Man by Means of Radioactive Krypton

The measurement of cerebral blood flow by means of the nitrous oxide method of Kety and Schmidt (1) or the krypton-85 (Kr85) technique of Lassen and Munck (2) requires a steady state of at least ten minutes, for it is not until the end of such a period that the uptake of the gas by the brain can be estimated indirectly from its concentration in cerebral venous blood. These methods are, therefor...

متن کامل

Measurement of Myocardial Blood Flow in Animals and Man by Selective Injection of Radioactive Inert Gas into the Coronary Arteries.

• The Kety-Schmidt method for measurement of regional blood flow was first applied to the heart by Eckenhoff et al. These investigators employed coronary sinus catheterization to measure myocardial blood flow with nitrous oxide. The use of a radioactive gas and an external detector for the measurement of organ blood flow was investigated by Conn, Lewis et al., and Lassen et al. The radioactive ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 16  شماره 

صفحات  -

تاریخ انتشار 1965