Techniques for intracranial stent navigation in patients with tortuous vessels.

نویسندگان

  • Tae Hong Lee
  • Chang Hwa Choi
  • Kyung-Pil Park
  • Sang Min Sung
  • Sang Won Lee
  • Byung-Hee Lee
  • Dong Hyun Kim
  • Hak Jin Kim
  • Chang Won Kim
  • Suk Kim
چکیده

BACKGROUND AND PURPOSE In some patients with stenosis of an intracranial artery, navigating the balloon or stent-delivery system is difficult of tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries Our purpose was to describe techniques of intracranial stent placement that help in navigating the stent-delivery system in tortuous vessels. METHODS Between May 1998 and June 2004, 73 symptomatic stenotic (>50%) intracranial arteries were successfully treated with stent-assisted angioplasty. In 11 cases, standard techniques of navigating the stent-delivery system into the intended lesion failed because of vascular tortuosity. In these difficult cases, several techniques were used to overcome the tortuosity. Five lesions were located in the middle cerebral arteries, four were in the supraclinoid internal carotid arteries, and two were in the distal vertebral arteries. RESULTS In all difficult cases, stents were successfully placed in the intracranial artery by using several techniques: 1) waiting method in which we waited for 20-30 minutes after advancement of the microwire across the lesion, 2) the double-wire technique, and 3) the coaxial double-guiding catheter technique. The waiting method made smooth stent navigation possible in five cases, the double-wire technique was successful in four cases, and the coaxial double-guiding catheter technique was effective in two cases. No technique-related complications occurred. CONCLUSION In difficult cases in which standard techniques of navigating the stent-delivery system into the intended lesion fail because of vascular tortuosity, our techniques were useful methods for intracranial stent navigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stiff guide technique: technical report and illustrative case.

Endovascular techniques are gaining wider acceptance in the treatment of intracranial lesions. Tortuous vasculature is a common reason for failure to treat an intracranial lesion, especially when balloon catheters or stents are used. In these cases, the guiding catheter often buckles into the aorta during an attempt to place the balloon or stent. In our experience, a stiff wire can be used to s...

متن کامل

Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization.

BACKGROUND AND PURPOSE Endovascular treatment of broad-neck intracranial aneurysms with detachable coils requires special techniques. Placement of a stent over the aneurysm neck and secondary coil embolization prevents coil migration and allows attenuated packing of the coils. However, access for the stent-delivery system can be technically limited in tortuous anatomy. We present six cases of b...

متن کامل

Novel Use of the GuideLiner Catheter to Deliver Rotational Atherectomy Burrs in Tortuous Vessels

Rotational atherectomy (RA) for heavily calcified lesions is essential for improved stent delivery and stent expansion. In tortuous vessels it is often difficult to advance the burr without rotation and possible injury to the endothelium of healthy vessel. The GuideLiner catheter, a child in mother catheter, has recently been used to allow for increased support for delivery of stents through to...

متن کامل

Brain aneurysms and arteriovenous malformations: advancements and emerging treatments in endovascular embolization.

BACKGROUND AND PURPOSE Brain aneurysms and vascular malformations can cause cerebral hemorrhages, with devastating consequences for the patients and their families. Since the development of microcatheters and materials used for endovascular embolization, we have witnessed a rapid advancement in the technology and in the number or patients treated with this approach. The aim of this review is to...

متن کامل

Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience.

BACKGROUND AND PURPOSE Currently available stents for intracranial use usually are balloon-expandable coronary stents that carry the risk of damaging a dysplastic segment of the artery, with potential vessel rupture. We assessed the technical feasibility and efficacy of the combined application of a flexible, self-expanding neurovascular stent and detachable coils in the management of wide-neck...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 2005