Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study

نویسندگان

  • Andrej N Nikoloski
  • Anthony L Osbrough
  • Piers J Yates
چکیده

BACKGROUND Unstable proximal femoral fractures are common and challenging for the orthopaedic surgeon. Often, these are treated with intramedullary nails. The most common mode of failure of any device to treat these fractures is cut-out. The Synthes proximal femoral nail antirotation (PFNA) is unique because it is the only proximal femoral intramedullary nail which employs a helical blade in lieu of a lag screw. The optimal tip-apex distance is 25 mm or less for a dynamic hip screw. The optimal blade tip placement is not known for the PFNA. AIM The aim of this study is to determine if the traditional tip-apex distance rule (<25 mm) applies to the PFNA. METHOD A retrospective study of all proximal femoral fractures treated with the PFNA in Western Australian public teaching hospitals between August 2006 and October 2007 was performed. Cases were identified from company and theatre implant use records. Patient demographic data was obtained from hospital records. Fractures were classified according to Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of Internal Fixation. Fracture reduction, distal locking type and blade position within the head (tip-apex distance and Cleveland zone) were recorded from the intraoperative and immediate postoperative radiographs. Postoperative radiographs obtained in the routine treatment of patients were studied for review looking primarily for cut-out. Clinical outcomes were measured with the Oxford hip score. RESULTS One hundred eighty-eight PFNAs were implanted during the study period, with 178 cases included in this study. Ninety-seven patients could be followed up clinically. There were 18 surgical implant-related failures (19%). The single most common mode of failure was cut-out in six cases (6.2%). Three cut-outs (two medial perforation and one varus collapse) occurred with tip-apex distance (TAD) less than 20 mm. There was no cut-out in cases where the TAD was from 20-30 mm. There were three implant-related failures (nail fracture, missed nail and loose locking screw), four implant-related femoral fractures, two non-unions, two delayed unions and one loss of reduction. CONCLUSION The PFNA is a suitable fixation device for the treatment of unstable proximal femoral fractures. There were still a relatively large number of cut-outs, and the tip-apex distance in the failures showed a bimodal distribution, not like previously demonstrated with dynamic hip screw. We propose that the helical blade behaves differently to a screw, and placement too close to the subchondral bone may lead to penetration through the head.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fixation of intertrochanteric femur fractures using Proximal Femoral Nail Antirotation (PFNA) in the lateral decubitus position without a traction table.

OBJECTIVE The aim of this study was to evaluate whether intertrochanteric femur fractures can be reduced and nailed properly in the lateral decubitus position using Proximal Femoral Nail Antirotation (PFNA) as a fixation device without the use of a traction table. METHODS The study included 207 patients (81 male and 126 female; mean age: 75 years, range: 22 to 95 years). According to the Evan...

متن کامل

Failure of PFNA: helical blade perforation and tip-apex distance.

Since the clinical introduction of proximal femoral nail antirotation (PFNA) by AO group in 2004 and PFNA-II (Asian version) in 2008, this type of cephalomedullary nail with single head-neck helical blade were commonly used in unstable pertrochanteric and intertrochanteric fractures in geriatric patients. Recently, severe complications of helical blade perforation through the femoral head, into...

متن کامل

Radiographic Outcomes of Osteosynthesis Using Proximal Femoral Nail Antirotation (PFNA) System in Intertrochanteric Femoral Fracture: Has PFNA II Solved All the Problems?

PURPOSE We evaluated the geometric discrepancies between the proximal femur in Koreans and two types of proximal femoral nail using plain radiographs. MATERIALS AND METHODS A total of 100 consecutive patients (38 treated with proximal femoral nail antirotation [PFNA], 62 PFNA II) with intertrochanteric fracture were retrospectively identified. The minimum follow up period was 32 months. The g...

متن کامل

Proximal Femoral Nail Antirotation in Treatment of Intertrochanteric Hip Fractures: a Retrospective Study in 113 Patients

INTRODUCTION The best treatment for intertrochanteric fractures remains controversial. Many methods have been recommended. AIM We aimed to assess the results of osteosynthesis using the Proximal Femoral Nail Antirotation (PFNA) system. PATIENTS AND METHODS We retrospectively analyzed 113 consecutive patients with intertrochanteric fractures treated with PFNA. Fractures were classified in ac...

متن کامل

The Asia proximal femoral nail antirotation versus the standard proximal femoral antirotation nail for unstable intertrochanteric fractures in elderly Chinese patients.

BACKGROUND The best options of internal fixation for unstable intertrochanteric fractures in elderly Chinese patients remain controversial. The Asia proximal femoral nail antirotation (PFNA-II) was specifically designed for Asian patients, which could be more effective than the regular proximal femoral nail antirotation (PFNA). Compared to PFNA, whether PFNA-II is associated with shorter operat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013