Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method

نویسندگان

  • Yongjun Jo
  • Soo Hwa Kim
  • Kwangsang Koh
  • Jongmoon Park
  • Yang Bo Shim
  • Jihyang Lim
  • Yonggoo Kim
  • Yeon-Joon Park
  • Kyungja Han
چکیده

BACKGROUND Hematology analyzers may ineffectively recognize abnormal cells, and manual differential counts may be imprecise for leukopenic samples. We evaluated the efficacy of the Hematoflow method for determining the leukocyte differential in leukopenic samples and compared this method with the manual differential method. METHODS We selected 249 blood samples from 167 patients with leukopenia (WBC counts, 500-2,000/µL) for analysis in this study. The EDTA-anticoagulated blood samples were analyzed using an automatic blood cell counter (DxH800; Beckman Coulter, USA) and flow cytometry (FC 500; Beckman Coulter) by using Cytodiff reagent and analysis software (Beckman Coulter). Hematoflow results were selected or calculated from DxH800 and Cytodiff results. Two trained pathologists performed a manual differential count by counting 50-100 cells. RESULTS The precision of the Hematoflow method was superior to that of the manual method in counting 5 leukocyte subpopulations, immature granulocytes (IGs), and blasts. Blasts were detected in all 45 cases (100%) by Hematoflow. The correlation of the Cytodiff blast count to the reference count was high (r = 0.8325). For all other cell populations, the correlation of the Hematoflow results with the reference count was stronger than that of the other manual counts with the reference count. CONCLUSIONS The Hematoflow differential counting method is more reproducible and sensitive than manual counting, and is relatively easy to perform. In particular, this method detected leukemic blasts more sensitively than manual differential counts. The Hematoflow method is a very useful supplement to automated cell counting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

White blood cell differential counts in severely leukopenic samples: a comparative analysis of different solutions available in modern laboratory hematology

BACKGROUND We evaluated the efficacy of white blood cell (WBC) differential counts in severely leukopenic samples by the Hematoflow method and by automated hematology analyzers and compared the results with manual counts. METHODS EDTA-anticoagulated blood samples (175 samples) with WBC counts of 40-990/µL were selected. Hematoflow differential counts were performed in duplicates employing flo...

متن کامل

Evaluation of early post-transplant leukocyte recovery using the undiluted erythrocyte lysing technique.

The undiluted erythrocyte lysing technique was evaluated to see if it provides more accurate total leukocyte counts and differential leukocyte counts of severely leukopenic blood samples, in order to detect the onset of hematopoietic recovery after stem cell transplantation. Leukocyte counts using the conventional automated cell counting technique were found to be inaccurate, especially in bloo...

متن کامل

Analysis of Free Vibration Sector Plate Based on Elastic Medium by using New Version of Differential Quadrature Method

The new version of differential quadrature (DQ) method is extended to analyze the free vibration of thin sector orthotropic plates on the Pasternak elastic foundation with various sector angles and elastic parameters. Detailed formulations are given. Comparisons are made with existing analytical and/or numerical data. Numerical results indicate that convergence can be achieved with increasing i...

متن کامل

Chemometrics-enhanced Kinetic Spectrophotometric Method for Simultaneous Determination of Ag+, Cu2+ and Ni2+ Ions in Some Medicinal Plants by Dimethyl 2,2’-(ethan-1,2-diylbis1)bis(cyclopent-1-ene-1-carbodithioate)

The metal ions constituents in plants reliable for determination of their medicinal, nutritional and toxicity properties. A novel, simple and accurate spectrophotometric method was developed for the simultaneous determination of Ag+, Cu2+ and Ni2+ ions in different medicinal plants without prior separation steps. This method was based on the different kinetic characteristics between the reactio...

متن کامل

A sensitive method for electrochemical determination of molybdenum (VI) in plant foodstuff samples using Ni0.5Zn0.5Fe2O4 nanocomposite modified carbon paste electrode

In the present study, a new chemically modified carbon paste electrode (CPE) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of Mo (VI) using differential pulse voltammetry. The electrode was prepared using magnetic nickel zinc ferrite nanocomposite (Ni0.5Zn0.5Fe2O4), as the modifier in CPE (Ni0.5Zn0.5Fe2O4/CPE). Mo (VI) was determined after preconcentr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2011