In vivo measurement of bending stiffness in fracture healing

نویسندگان

  • Reiner Hente
  • Jacques Cordey
  • Stephan M Perren
چکیده

BACKGROUND Measurement of the bending stiffness a healing fracture represents a valid variable in the assessment of fracture healing. However, currently available methods typically have high measurement errors, even for mild pin loosening. Furthermore, these methods cannot provide actual values of bending stiffness, which precludes comparisons among individual fractures. Thus, even today, little information is available with regards to the fracture healing pattern with respect to actual values of bending stiffness. Our goals were, therefore: to develop a measurement device that would allow accurate and sensitive measurement of bending stiffness, even in the presence of mild pin loosening; to describe the course of healing in individual fractures; and help to evaluate whether the individual pattern of bending stiffness can be predicted at an early stage of healing. METHODS A new measurement device has been developed to precisely measure the bending stiffness of the healing fracture by simulating four-point-bending. The system was calibrated on aluminum models and intact tibiae. The influence of pin loosening on measurement error was evaluated. The system was tested at weekly intervals in an animal experiment to determine the actual bending stiffness of the fracture. Transverse fractures were created in the right tibia of twelve sheep, and then stabilized with an external fixator. At ten weeks, bending stiffness of the tibiae were determined in a four-point-bending test device to validate the in-vivo-measurement data. RESULTS In-vivo bending stiffness can be measured accurately and sensitive, even in the early phase of callus healing. Up to a bending stiffness of 10 Nm/degree, measurement error was below 3.4% for one pin loose, and below 29.3% for four pins loose, respectively. Measurement of stiffness data over time revealed a significant logarithmic increase between the third and seventh weeks, whereby the logarithmic rate of change among sheep was similar, but started from different levels. Comparative measurements showed that early individual changes between the third and fourth weeks can be used as a predictor of bending stiffness at seven weeks (r = 0.928) and at ten weeks (r = 0.710). CONCLUSION Bending stiffness can be measured precisely, with less error in the case of pin loosening. Prediction of the future healing course of the individual fracture can be assessed by changes from the third to the fourth week, with differences in stiffness levels. Therefore, the initial status of the fracture seems to have a high impact on the individual healing course.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new method for measurement of bone bending stiffness non-invasively by echo tracking

INTRODUCTION: We have attempted to noninvasively assess the bone deformation angle of a fracture healing site under a load using Echo tracking (ET). The ET method can be used to evaluate the bending stiffness, but previous studies [1] have not validated the accuracy of bending stiffness as measured by ET because this was in vivo study. In order to evaluate the accuracy of bending stiffness as d...

متن کامل

A Novel Shape Memory Plate Osteosynthesis for Noninvasive Modulation of Fixation Stiffness in a Rabbit Tibia Osteotomy Model

UNLABELLED Nickel-titanium shape memory alloy (NiTi-SMA) implants might allow modulating fracture healing, changing their stiffness through alteration of both elastic modulus and cross-sectional shape by employing the shape memory effect (SME). HYPOTHESES a novel NiTi-SMA plate stabilizes tibia osteotomies in rabbits. After noninvasive electromagnetic induction heating the alloy exhibits the ...

متن کامل

Clinical implications of stiffness and strength changes in fracture healing.

In the assessment of fracture healing by monitoring stiffness with vibrational analysis or instrumented external fixators, it has been assumed that there is a workable correlation between stiffness and strength. We used four-point bending tests to study time-related changes in stiffness and strength in healing tibial fractures in sheep. We aimed to test the validity of the measurement of stiffn...

متن کامل

A Practical Fracture Healing Endpoint Assessment Criterion For Tibial Fractures Treated With External Fixation

There is a need for a quick, simple, repeatable, but quantifiable assessment of fracture healing end-point that does not rely on the use of x-rays or on un-measured manipulation. This paper presents an argument to support a “maximum of one degree of bending” criterion. We propose that a mid-shaft tibial facture may be considered healed when it is not possible to bend the fracture by more than 1...

متن کامل

Numerical Simulation of Callus Healing for Optimization of Fracture Fixation Stiffness

The stiffness of fracture fixation devices together with musculoskeletal loading defines the mechanical environment within a long bone fracture, and can be quantified by the interfragmentary movement. In vivo results suggested that this can have acceleratory or inhibitory influences, depending on direction and magnitude of motion, indicating that some complications in fracture treatment could b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2003