Measurements of laser light attenuation following cryogen spray cooling spurt termination.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatological surgery. However, while CSC can protect the epidermis from non-specific thermal damage, the cryogen film on the skin surface may pose a potential problem of laser light attenuation due to optical scattering. STUDY DESIGN/MATERIALS AND METHODS This study is focused on measuring the light transmittance changes that occur following cryogen spurt termination. The wavelengths studied were chosen for their clinical relevance to treatment of hypervascular skin lesions (594 nm) and laser-assisted hair removal (785 nm). Following delivery of cryogen spurts to the surface of an epoxy skin phantom, continuous records of light transmittance for 594 and 785 nm were obtained using an integrating sphere-based light collection apparatus. RESULTS Shortly after spurt termination, there was negligible light attenuation by the cryogen film at the two wavelengths studied. CONCLUSIONS For the typical clinical use of a 30 milliseconds spurt duration and 30 milliseconds delay between spurt termination and delivery of the laser pulse, a minimum average transmittance value of approximately 97% was measured.
منابع مشابه
Effect of ambient humidity on light transmittance through skin phantoms during cryogen spray cooling.
Cryogen spray cooling (CSC) is a technique employed to reduce the risk of epidermal damage during dermatologic laser surgery. However, while CSC protects the epidermis from non-specific thermal damage, it might reduce the effective fluence reaching the target chromophore due to scattering of light by the spray droplets and subsequent water condensation/freezing on the skin surface. The objectiv...
متن کاملDynamic Behavior of Cryogen Spray Cooling: Effect of Spray Distance
Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic surgery. During CSC, skin surface is cooled by a short spurt of refrigerant R134a with boiling point of –26.2 C. Since R134a is volatile in open atmospheric conditions, the atomized liquid droplets undergo continuous evaporation as they fly in air, leading to a lost momentum and mass. Therefor...
متن کاملEpidermal protection with cryogen spray cooling during high fluence pulsed dye laser irradiation: an ex vivo study.
BACKGROUND AND OBJECTIVE Higher laser fluences than currently used in therapy (5-10 J/cm(2)) are expected to result in more effective treatment of port wine stain (PWS) birthmarks. However, higher incident fluences increase the risk of epidermal damage caused by absorption of light by melanin. Cryogen spray cooling offers an effective method to reduce epidermal injury during laser irradiation. ...
متن کاملDynamic Measurements of Laser Light Attenuation by Cryogen Film and Frost Formation
The purpose of this study was to investigate the dynamics of laser light attenuation during cryogen spray cooling (CSC). Two detection schemes were used to approximate collimated and diffuse light transmittance measurements of continuous-wave (λ = 594 nm) and pulsed (λ = 585 nm) laser light during application of short (20-100 ms duration) cryogen spurts on a glass substrate. High-speed video im...
متن کاملSpray and Cooling Dynamics of Cryogen Sprays Impinging on a Human Skin Model
The objective of the present work is to correlate the timedependent flow characteristics of cryogen sprays to the induced thermal dynamics at the surface of a human skin model. First, a numerical analysis to evaluate our skin model is carried out. Next, diameter and axial velocity of droplets impinging onto the skin model are measured. Diameter, velocity and surface temperature are acquired sim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lasers in surgery and medicine
دوره 32 2 شماره
صفحات -
تاریخ انتشار 2003