Performance of conventional biometry vs. integrated laser interferometry with keratometry device in intraocular lens measurement.

نویسندگان

  • Sabong Srivannaboon
  • Morakot Tanehsakdi
چکیده

OBJECTIVE To compare the performance of the Conventional Biometry (CB) (Applanation Ultrasound and Keratometry) and the Integrated Laser Interferometry with Keratometry Device (LI) in the measurement of Intraocular Lens (IOL). MATERIAL AND METHOD A prospective study of 100 eyes in 50 cataract patients was conducted. The IOL measurement using the LIfollowed by the CB was done on all eyes. The keratometry (K), axial length (AL), IOL power, and time required for both methods were compared in the same subject by ANOVA with repeated measurement. RESULTS The LI could not obtain the AL in 14%. There were 21% that the signal to noise ratio was below 1.6. The AL obtained by the LI was significant higher compared to the CB by mean of 0.28 mm (p < 0.05). The K showed no statistically significant difference (p = 0.05). There was statistically significantly higher IOL power calculated by the LI compared to the CB by mean of 0.63 D (p < 0.05). The time required for the LI was 2.77 +/- 1.44 min and the CB was 9.63 +/- 3.82 min (p < 0. 05). CONCLUSION The LI required less time than the CB in measurement of the IOL but could not measure the AL in the group of patients with dense cataracts. The LI give a higher IOL power compared to the CB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Comparison of IOL power calculation and refractive outcome after laser refractive cataract surgery with a femtosecond laser versus conventional phacoemulsification.

PURPOSE To compare intraocular lens (IOL) power calculation and refractive outcome between patients who underwent laser refractive cataract surgery with a femtosecond laser and those with conventional cataract surgery. METHODS In this prospective study, 77 eyes from 77 patients underwent laser refractive cataract surgery (laser group; Alcon LenSx femtosecond laser), and conventional cataract ...

متن کامل

Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included...

متن کامل

Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

PURPOSE To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). SETTING Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Pa...

متن کامل

Comparison of a new optical biometer and a standard biometer in cataract patients

BACKGROUND Cataract surgery is the most common surgical procedure in ophthalmology. Biometry data and accurate intraocular lens (IOL) calculations are very important in achieving the desired refractive outcomes. The aim of this study was to compare measurements using a new optical low coherence reflectometry (OLCR) biometer (OA-2000) and the gold standard partial coherence interferometry (PCI) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Medical Association of Thailand = Chotmaihet thangphaet

دوره 90 11  شماره 

صفحات  -

تاریخ انتشار 2007