Intra and inter-session reliability of rapid Transcranial Magnetic Stimulation stimulus-response curves of tibialis anterior muscle in healthy older adults

نویسندگان

  • Elisabetta Peri
  • Emilia Ambrosini
  • Vera Maria Colombo
  • Mark van de Ruit
  • Michael J Grey
  • Marco Monticone
  • Giorgio Ferriero
  • Alessandra Pedrocchi
  • Giancarlo Ferrigno
  • Simona Ferrante
چکیده

OBJECTIVE The clinical use of Transcranial Magnetic Stimulation (TMS) as a technique to assess corticospinal excitability is limited by the time for data acquisition and the measurement variability. This study aimed at evaluating the reliability of Stimulus-Response (SR) curves acquired with a recently proposed rapid protocol on tibialis anterior muscle of healthy older adults. METHODS Twenty-four neurologically-intact adults (age:55-75 years) were recruited for this test-retest study. During each session, six SR curves, 3 at rest and 3 during isometric muscle contractions at 5% of maximum voluntary contraction (MVC), were acquired. Motor Evoked Potentials (MEPs) were normalized to the maximum peripherally evoked response; the coil position and orientation were monitored with an optical tracking system. Intra- and inter-session reliability of motor threshold (MT), area under the curve (AURC), MEPmax, stimulation intensity at which the MEP is mid-way between MEPmax and MEPmin (I50), slope in I50, MEP latency, and silent period (SP) were assessed in terms of Standard Error of Measurement (SEM), relative SEM, Minimum Detectable Change (MDC), and Intraclass Correlation Coefficient (ICC). RESULTS The relative SEM was ≤10% for MT, I50, latency and SP both at rest and 5%MVC, while it ranged between 11% and 37% for AURC, MEPmax, and slope. MDC values were overall quite large; e.g., MT required a change of 12%MSO at rest and 10%MSO at 5%MVC to be considered a real change. Inter-sessions ICC were >0.6 for all measures but slope at rest and MEPmax and latency at 5%MVC. CONCLUSIONS Measures derived from SR curves acquired in <4 minutes are affected by similar measurement errors to those found with long-lasting protocols, suggesting that the rapid method is at least as reliable as the traditional methods. As specifically designed to include older adults, this study provides normative data for future studies involving older neurological patients (e.g. stroke survivors).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal

Introduction: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal ...

متن کامل

A Higher Number of TMS-Elicited MEP from a Combined Hotspot Improves Intra- and Inter-Session Reliability of the Upper Limb Muscles in Healthy Individuals

We aimed to determine, using transcranial magnetic stimulation (TMS), the number of elicited motor evoked potentials (MEPs) that induces the highest intra- and inter-sessions reliability for the extensor carpi radialis (ECR) and first dorsal interosseus (FDI) muscles. Twelve healthy subjects participated in this study on two separate days. Single pulse magnetic stimuli were triggered with Magst...

متن کامل

Inter-pulse Interval Affects the Size of Single-pulse TMS-induced Motor Evoked Potentials: a Reliability Study

Introduction: Measuring the size of motor evoked potentials (MEPs) induced by transcranial magnetic stimulation (TMS) is an investigational technique to show the level of corticospinal excitability however, some of the fundamental methodological aspects of TMS (such as the effects of inter-pulse intervals (IPI) on MEP size) are not fully understood, this issue raises concerns about the re...

متن کامل

Prediction of the response to repetitive transcranial magnetic stimulation by spectral powers of prefrontal regions of brain.

Introduction: Quantitative assessments of the effects induced by repetitive transcranial magnetic stimulation (rTMS) are crucial to develop more efficient and personalized treatments. Objectives: To determine the spectral powers of different subbands of EEG correlated with treatment response to rTMS.   Materials and Methods: the spectral powers of different...

متن کامل

Reliability of lower limb motor evoked potentials in stroke and healthy populations: how many responses are needed?

OBJECTIVE To determine the intra- and inter-session reliability of motor evoked potential (MEP) size parameters in the lower limb of patients with stroke, focussing on the number of MEPs collected and the method of measuring MEP size. METHODS Transcranial magnetic stimulation was used to elicit MEPs in the soleus muscle of patients with stroke (n=13) and age-matched healthy participants (n=13...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017