Combined application of simulated reuse and quantitative carrier tests to assess high-level disinfection: experiments with an accelerated hydrogen peroxide-based formulation.

نویسندگان

  • Syed A Sattar
  • Olusola Adegbunrin
  • Jose Ramirez
چکیده

BACKGROUND Heat-sensitive medical devices require chemical disinfection between patients, and certain formulations for this purpose can be reused for several days. Because dilution, evaporation, and breakdown or neutralization of active ingredients can occur during reuse, it is vital to ensure that the solution retains its broad-spectrum germicidal activity even at the end of the recommended reuse period. OBJECTIVE The purpose of this study was to combine the US Environmental Protection Agency's and the Food and Drug Administration's recommended simulated reuse method with recently developed quantitative carrier tests (QCT) to assess the broad-spectrum germicidal activity of a 7% solution of accelerated hydrogen peroxide (pH 2.9) stressed for 14 days. MATERIALS AND METHODS On alternate days baths with 3 lots of the test formulation were stressed by the addition of bacteria (Salmonella choleraesuis, Staphylococcus aureus, and Pseudomonas aeruginosa ) on glass beads and spores (Bacillus subtilis and Clostridium sporogenes ) on metallic penicylinders. In addition, one set of respiratory therapy equipment was subjected to 3 daily cycles of disinfection in each bath. The pH and H(2)O(2) levels in the test samples were measured, and they were also subjected to QCTs for their sporicidal, bactericidal, virucidal, fungicidal, and mycobactericidal activities. RESULTS After 14 days of reuse, the pH of the test solutions remained essentially unchanged. Although the level of H(2)O(2) dropped from a high of 7.66% to as low as 6.40%, all lots showed the required level of broad-spectrum germicidal activity after 14 days of stress. CONCLUSIONS The stress test and QCT were successfully combined in demonstrating the broad-spectrum germicidal activity of a high-level disinfectant subjected to 14 days of simulated reuse.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new peroxide-based flexible endoscope-compatible high-level disinfectant.

Semicritical medical devices such as flexible endoscopes require high-level disinfection between each use, and glutaraldehyde is often used for this purpose because of its favorable materials compatibility. However, workplace safety and the relatively slow microbicidal activity of such formulations remain a concern. Although recently introduced substitutes based on 0.55% ortho-phthaldehyde (OPA...

متن کامل

Biobleaching of Bagasse Pulp with Xylanase Enzymes and Hydrogen Peroxide

The effect of the operating conditions (temperature, time, pH, enzyme level and pulp consistency) used in the enzymatic step of a XP (Cartazyme-hydrogen peroxide) sequence for bleaching Kraft pulp from bagasse on various properties of the resulting pulp and paper sheet products was studied. The quality of bagasse used, was examined by its yield, brightness,viscosity and the Kappa number. Finall...

متن کامل

Effectiveness of a novel ozone-based system for the rapid high-level disinfection of health care spaces and surfaces.

BACKGROUND Vapor-based fumigant systems for disinfection of health care surfaces and spaces is an evolving technology. A new system (AsepticSure) uses an ozone-based process to create a highly reactive oxidative vapor with broad and high-level antimicrobial properties. METHODS Ozone gas at 50-500 ppm was combined with 3% hydrogen peroxide vapor in a test chamber and upscaled in rooms measurin...

متن کامل

مقایسه کارایی واکنش­‌گر فنتون و فنتون تغییر یافته با مس در گندزدایی  فاضلاب خام به منظور استفاده مجدد در کشاورزی

MicrosoftInternetExplorer4 Background and Objectives: Irrigation of agricultural crops using wastewater will increase, in some cases, their growth by 40 to 60 percent. However, this has a high risks for human health because of the presence of higher number of pathogenic organisms. The main purpose of this study was to investigate the feasibility use of Fenton and modified Fenton with coppe...

متن کامل

Susceptibility of HPV16 and 18 to high level disinfectants indicated for semi‐critical ultrasound probes

Ultrasound probes used in endocavitary procedures have been shown to be contaminated with high-risk HPV after routine use and HPV is also known to be resistant to some high level disinfectants (HLDs). This study compared efficacy of two leading ultrasound probe HLD methods; liquid ortho-phthalaldehyde (Cidex® OPA) and an automated device using sonicated hydrogen peroxide (trophon® EPR) against ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of infection control

دوره 30 8  شماره 

صفحات  -

تاریخ انتشار 2002