Sol–gel-derived thick-film conductometric biosensor for urea determination in serum

نویسندگان

  • Won-Yong Lee
  • Seung-Ryeol Kim
  • Tae-Han Kim
  • Kang Shin Lee
  • Min-Chol Shin
  • Je-Kyun Park
چکیده

A conductometric urea biosensor based on sol–gel-immobilized urease on a screen-printed inter-digitated array (IDA) electrode has been developed. The screen-printed thick-film IDA electrode has proven to be an excellent conductometric transducer in which the admittance signal was dominated by the conductance signal and the resulting dynamic range was wide enough to be employed for the construction of conductometric urea biosensor. Urease was immobilized by a conventional sol–gel process using tetramethyl orthosilicate as a precursor. The sol–gel-derived urea biosensor showed a reasonably wide linear dynamic range 0.03–2.5 mM in 5.0 mM imidazole–HCl buffer at pH 7.5 (detection limit = 30 mM, signal : noise = 2), thus enabling it to be used to monitor urea in a diluted serum sample with the differential measurement format consisting of an active IDA electrode with sol–gel-immobilized urease and a control IDA electrode with sol–gel-immobilized bovine serum albumin. The urea biosensor exhibited good sensor-to-sensor reproducibility (4.4%) and storage stability (63% of its original activity retained after 25 days). The coupling of the sol–gel immobilization method and screen-printing technology can offer mass production of a durable urea biosensor. ©2000 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode

Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...

متن کامل

A Urea Biosensor from Stacked Sol-Gel Films with Immobilized Nile Blue Chromoionophore and Urease Enzyme

An optical urea biosensor was fabricated by stacking several layers of sol-gelfilms. The stacking of the sol-gel films allowed the immobilization of a Nile Bluechromoionophore (ETH 5294) and urease enzyme separately without the need of anychemical attachment procedure. The absorbance response of the biosensor was monitoredat 550 nm, i.e. the deprotonation of the chromoionophore. This multi-laye...

متن کامل

Sol-gel spin coating derived ZnO thin film to sense the acetic acid vapor

ZnO thin film of 80 nm thickness was deposited by the sol-gel spin coating method on SiO2/Si substrate and subsequently post-annealed at 500°C with a flow of oxygen for 60 min. Crystallographic structure of the sample was characterized by X-ray diffraction (XRD) method while a field emission scanning electron microscope (FESEM) was used to investigate the surface physical morphology ...

متن کامل

Sol-gel spin coating derived ZnO thin film to sense the acetic acid vapor

ZnO thin film of 80 nm thickness was deposited by the sol-gel spin coating method on SiO2/Si substrate and subsequently post-annealed at 500°C with a flow of oxygen for 60 min. Crystallographic structure of the sample was characterized by X-ray diffraction (XRD) method while a field emission scanning electron microscope (FESEM) was used to investigate the surface physical morphology ...

متن کامل

A Novel Conductometric Urea Biosensor with Improved Analytical Characteristic Based on Recombinant Urease Adsorbed on Nanoparticle of Silicalite.

Development of a conductometric biosensor for the urea detection has been reported. It was created using a non-typical method of the recombinant urease immobilization via adsorption on nanoporous particles of silicalite. It should be noted that this biosensor has a number of advantages, such as simple and fast performance, the absence of toxic compounds during biosensor preparation, and high re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999