In the early stages of development of a new Active Pharmaceutical Ingredient (API), insufficient material quantity is available for addressing processing issues, and it is highly desirable to be able to assess processability issues using the smallest possible powder sample quantity. A good example is milling of new active pharmaceutical ingredients. For particle breakage that is sensitive to strain rate, impact testing is the most appropriate method. However, there is no commercially available single particle impact tester for fine particulate solids. In contrast, dry powder dispersers, such as the Scirocco disperser of the Malvern Mastersizer 2000, are widely available, and can be used for this purpose, provided particle impact velocity is known. However, the distance within which the particles can accelerate before impacting on the bend is very short and different particle sizes accelerate to different velocities before impact. As the breakage is proportional to the square of impact velocity, the interpretation of breakage data is not straightforward and requires an analysis of particle velocity as a function of size, density and shape. We report our work using an integrated experimental and CFD modelling approach to evaluate the suitability of this device as a grindability testing device, with the particle sizing being done immediately following dispersion by laser diffraction. Aspirin, sucrose and α-lactose monohydrate are tested using narrow sieve cuts in order to minimise variations in impact velocity. The tests are carried out at eight different air nozzle pressures. As intuitively expected, smaller particles accelerate faster and impact the wall at a higher velocity compared to the larger particles. However, for a given velocity the extent of breakage of larger particles is larger. Using a numerical simulation based on CFD, the relationship between impact velocity and particle size and density has been established assuming a spherical shape, and using one-way coupling, as the particle concentration is very low. Taking account of these dependencies, a clear unification of the change in the specific surface area as a function of particle size, density and impact velocity is observed, and the slope of the fitted line gives a measure of grindability for each material. The trend of data obtained here matches the one obtained by single particle impact testing. Hence aerodynamic dispersion of solids by the Scirocco disperser can be used to evaluate the ease of grindability of different materials.
منابع مشابه
New laboratory scale Grinding method to predict energy and the feed grindability of mill of Sarcheshmeh Copper Complex
One of the factors which are usually difficult to be measured in mills is the grindability and distribution of feed under real situation and in a short time. In the condition of achieving a fast and convenient way to determine these parameters, the proper relationship between energy, hardness and particle size distribution can be obtained. Feed hardness is one of the most important factors in g...
متن کاملCorrelations for the Grindability of the Ball Mill As a Measure of Its Performance
Ball mill is vital equipment in industries viz. mineral dressing, ore processing, fertilizers, food and diary, pharmaceuticals and many others. The present work involves a meticulous study of the effect of the various parameters on the performance of a ball mill. The parameters studied in this work are particle size, number of balls, time of grinding, particle density, and speed of the ball mil...
متن کاملScreening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology
Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of pharmaceutics
دوره 501 1-2 شماره
صفحات -
تاریخ انتشار 2016