A Prototype Ionization Profile Monitor for Rhic

نویسنده

  • R. Connolly
چکیده

Transverse beam profiles in the Relativistic Heavy-Ion Collider (RHIC) will be measured with ionization profile monitors (IPM’s). Each IPM collects and measures the distribution of electrons in the beamline resulting from residual gas ionization during bunch passage. The electrons are swept transversely from the beamline and collected on strip anodes oriented parallel to the beam axis. At each bunch passage the charge pulses are amplified, integrated, and digitized for display as a profile histogram. A prototype detector was tested in the injection line during the RHIC Sextant Test. This paper describes the detector and gives results from the beam tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam Lifetime Dependence on the Beam-Gas Interactions in RHIC

In the Relativistic Heavy ion Collider (RHIC) much larger background signals were occurring at BRAMS, one of the four experiments. This was especially pronounced at the time when vacuum conditions deteriorated due to the beam ionization profile monitor replacements. Recording the beam intensities during the store provided the beam lifetime. Predictions from the beam gas interactions to the abov...

متن کامل

Beam Transverse Profile Monitors for Ifmif-eveda

In the framework of the IFMIF-EVEDA project, a high deuteron beam intensity (125 mA 9 MeV) prototype accelerator will be built and tested at Rokkasho (Japan). CEA-Saclay group and CIEMAT-Madrid (Spain) are responsible for the beam instrumentation from the ion source to the beam dump. One of the most challenging diagnostic is the Beam Transverse Profile Monitor. Two kinds of monitor are investig...

متن کامل

RHIC Instrumentation

The Relativistic Heavy Ion Collider (RHIC) consists of two 3.8 km circumference rings utilizing 396 superconducting dipoles and 492 superconducting quadrupoles. Each ring will accelerate approximately 60 bunches of 10 protons to 250 GeV, or 10 fully stripped gold ions to 100 GeV/nucleon. Commissioning is scheduled for early 1999 with detectors for some of the 6 intersection regions scheduled fo...

متن کامل

A New Luminescence Beam Profile Monitor for Intense Proton and Heavy Ion Beams

A new luminescence beam profile monitor is realized in the polarized hydrogen gas jet target at the Relativistic Heavy Ion Collider (RHIC) facility. In addition to the spin polarization of the proton beam being routinely measured by the hydrogen gas jet, the luminescence produced by beam-hydrogen excitation leads to a strong Balmer series lines emission. A selected hydrogen Balmer line is spect...

متن کامل

Measurement of Ion Beam from Laser Ion Source for Rhic Ebis

Laser ion source (LIS) is a candidate of the primary ion source for the RHIC EBIS. LIS will provide intense charge state 1+ ions to the EBIS for further ionization. We measured plasma properties of a variety of atomic species from C to Au using the second harmonics of Nd:YAG laser (532 nm wave length, up to 0.5 J / 6 ns). Since properties of laser produced plasma is different from different spe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998