A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats

نویسندگان

  • Martin Schmoll
  • Ewald Unger
  • Manfred Bijak
  • Martin Stoiber
  • Hermann Lanmüller
  • Jonathan Charles Jarvis
چکیده

Direct measurements of muscular forces usually require a substantial rearrangement of the biomechanical system. To circumvent this problem, various indirect techniques have been used in the past. We introduce a novel direct method, using a lightweight (~0.5 g) miniature (3 x 3 x 7 mm) in-line load-cell to measure tension in the tibialis anterior tendon of rats. A linear motor was used to produce force-profiles to assess linearity, step-response, hysteresis and frequency behavior under controlled conditions. Sensor responses to a series of rectangular force-pulses correlated linearly (R2 = 0.999) within the range of 0-20 N. The maximal relative error at full scale (20 N) was 0.07% of the average measured signal. The standard deviation of the mean response to repeated 20 N force pulses was ± 0.04% of the mean response. The step-response of the load-cell showed the behavior of a PD2T2-element in control-engineering terminology. The maximal hysteretic error was 5.4% of the full-scale signal. Sinusoidal signals were attenuated maximally (-4 dB) at 200 Hz, within a measured range of 0.01-200 Hz. When measuring muscular forces this should be of minor concern as the fusion-frequency of muscles is generally much lower. The newly developed load-cell measured tensile forces of up to 20 N, without inelastic deformation of the sensor. It qualifies for various applications in which it is of interest directly to measure forces within a particular tendon causing only minimal disturbance to the biomechanical system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In‐situ measurements of tensile forces in the tibialis anterior tendon of the rat in concentric, isometric, and resisted co‐contractions

Tensile-force transmitted by the tibialis anterior (TA) tendon of 11 anesthetized adult male Wistar rats (body-mass: 360.6 ± 66.3 g) was measured in-situ within the intact biomechanical system of the hind-limb using a novel miniature in-line load-cell. The aim was to demonstrate the dependence of the loading-profile experienced by the muscle, on stimulation-frequency and the resistance to short...

متن کامل

CLINICAL OUTCOME OF ACL RECONSTRUCTION USING HAMSTRING TENDON AUTOGRAFT VERSUS TIBIALIS ANTERIOR TENDON ALLOGRAFT

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts.

PURPOSE Because allograft tendons used to replace a torn anterior cruciate ligament are in short supply, it is useful to explore other possible graft sources. The purpose of this study was to determine whether a graft formed from a loop of either an anterior or posterior tibialis tendon has structural, material, and viscoelastic properties similar to those of a double-looped semitendinosus and ...

متن کامل

Implantation increases tensile strength and collagen content of self-assembled tendon constructs.

Tissue-engineered tendons, derived from an autologous cell source, have the potential to provide an ideal replacement graft that is biologically compatible and has the ability to adapt to the specific mechanical requirements of the in vivo environment. Scaffold-free tendon constructs have been successfully engineered in vitro. However, when compared against native tendons the constructs demonst...

متن کامل

Repair of Chronic Tibialis Anterior Tendon Ruptures.

This article presents a novel technique for repair of chronic tibialis anterior tendon ruptures. All chronic tibialis anterior tendon ruptures reviewed were treated with this technique. Patients with chronic tibialis anterior tendon ruptures presenting to the authors' institution from 2006 to 2012 had preoperative and postoperative Foot and Ankle Ability Measure scores. The average follow-up ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017