Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping.

نویسندگان

  • E M Pedersen
  • E V Stenbøg
  • T Fründ
  • K Houlind
  • O Kromann
  • K E Sørensen
  • K Emmertsen
  • V E Hjortdal
چکیده

OBJECTIVE To measure caval and pulmonary flows at rest and immediately after exercise in patients with total cavopulmonary connection (TCPC). DESIGN An observational study using the patients as their own controls. SETTING Using a combination of magnetic resonance (MR) phase contrast techniques and an MR compatible bicycle ergometer, blood flow was measured in the superior vena cava, the tunnel from the inferior vena cava, and in the left and right pulmonary arteries during rest and on exercise (0.5 W/kg and 1.0 W/kg). PATIENTS Eleven patients aged 11.4 (4.6) years (mean (SD)) were studied 6.3 (3.8) years after TCPC operation. MAIN OUTCOME MEASURES Volume flow measured in all four branches of the TCPC connection during rest and exercise. RESULTS Systemic venous return (inferior vena cava plus superior vena cava) increased from 2.5 (0.1) l/min/m2 (mean (SEM)) to 4.4 (0.4) l/min/m2 (p < 0.05) during exercise, with even distribution to the two pulmonary arteries. At rest, inferior vena caval flow was higher than superior vena caval flow, at 1.4 (0.1) v 1.1 (0.1) l/min/m2 (p < 0.05). During exercise, inferior vena caval flow doubled (to 3.0 (0.3) l/min/m2) while superior vena caval flow only increased slightly (to 1.4 (0.1) l/min/m2) (p < 0.05). The increased blood flow mainly reflected an increase in heart rate. The inferior vena caval to superior vena caval flow ratio was 1.4 (0.1) at rest and increased to 1.8 (0.1) (p < 0.05) at 0.5 W/kg, and to 2.2 (0.2) at 1.0 W/kg (p < 0.05). CONCLUSIONS Quantitative flow measurements can be performed immediately after exercise using MR techniques. Supine leg exercise resulted in a more than twofold increase in inferior vena caval flow. This was equally distributed to the two lungs, indicating that pulmonary resistance rather than geometry decides flow distribution in the TCPC circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CONGENITAL HEART DISEASE Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping

Objective: To measure caval and pulmonary flows at rest and immediately after exercise in patients with total cavopulmonary connection (TCPC). Design: An observational study using the patients as their own controls. Setting: Using a combination of magnetic resonance (MR) phase contrast techniques and an MR compatible bicycle ergometer, blood flow was measured in the superior vena cava, the tunn...

متن کامل

Noninvasive quantification of fluid mechanical energy losses in the total cavopulmonary connection with magnetic resonance phase velocity mapping.

A major determinant of the success of surgical vascular modifications, such as the total cavopulmonary connection (TCPC), is the energetic efficiency that is assessed by calculating the mechanical energy loss of blood flow through the new connection. Currently, however, to determine the energy loss, invasive pressure measurements are necessary. Therefore, this study evaluated the feasibility of...

متن کامل

Accuracy of conventional oximetry for flow estimation in patients with superior cavopulmonary connection: a comparison with phase-contrast cardiac MRI.

BACKGROUND Cardiac catheterization is routinely used as a diagnostic tool in single ventricle patients with superior cavopulmonary connection. This physiology presents inherent challenges in applying the Fick principle to estimate flow. We sought to quantitatively define the error in oximetry-derived flow parameters using phase-contrast cardiac MRI (CMR) as a reference. METHODS AND RESULTS Th...

متن کامل

Effects of exercise and respiration on blood flow in total cavopulmonary connection: a real-time magnetic resonance flow study.

BACKGROUND Little is known about blood flow and its relationship to respiration during exercise in patients with total cavopulmonary connection (TCPC). METHODS AND RESULTS We studied 11 patients 12.4+/-4.6 years (mean+/-SD) of age 5.9+/-2.8 years (mean+/-SD) after TCPC operation. Real-time MRI was used to measure blood flow in the superior vena cava (SVC), inferior vena cava (IVC), and ascend...

متن کامل

Successful treatment of plastic bronchitis by selective lymphatic embolization in a Fontan patient.

Plastic bronchitis is a rare and often fatal complication of single-ventricle surgical palliation after total cavopulmonary connection. Although lymphatic abnormalities have been postulated to play a role in the disease process, the etiology and pathophysiology of this complication remain incompletely understood. Here we report on the etiology of plastic bronchitis in a child with total cavopul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 87 6  شماره 

صفحات  -

تاریخ انتشار 2002