A cone-beam computed tomography assessment of the efficacy of different irrigation devices for removal of silicone oil-based calcium hydroxide from root canal system
نویسندگان
چکیده
BACKGROUND Most often used intracanal medicament is calcium hydroxide (Ca(OH)2). Removal of Ca(OH)2 before obturation is mandatory. Different irrigation solutions and devices were tested in the previous study for this purpose. AIM The aim of this study was to evaluate the comparative efficacy of different irrigation techniques in removing intracanal medicament using cone-beam computed tomography (CBCT). MATERIALS AND METHODS Cleaning and shaping was carried out in 42 freshly extracted single-rooted mandibular first premolars using Protaper Rotary Files. Intracanal medicament (silicone oil-based Ca(OH)2 paste) was placed and left for 2 weeks in the root canal. Medicament was then removed by five different irrigation techniques: EndoActivator, EndoVac, ultrasonic irrigation with Endo-U-File, F-file, and Max-i-Probe needle. Changes in volume percentage were measured using CBCT and results were statistically analyzed using Levene's statistics and ANOVA. RESULTS Remnants of Ca(OH)2 were found in all experimental groups. No significant difference was detected among the groups. F-file showed maximum removal efficacy of approximately 48%. CONCLUSION (1) There is no statistically significant difference between any irrigation technique for removal of oil-based Ca(OH)2. (2) F-file demonstrated better results among all the other systems.
منابع مشابه
Efficacy of Different Irrigation Systems Used to Remove Calcium Hydroxide from the Root Canal
Introduction: The present study aimed to compare the cleaning efficacy of passive ultrasonic irrigation (PUI), self-adjusting file (SAF), EndoVac, and conventional syringe irrigation (CSI) techniques on Ca(OH)2 removal from the root canal. Methods: This study was conducted on the mesial roots of 36 human mandibular molar teeth. After 1 month, the Ca(...
متن کاملRetrievability of calcium hydroxide intracanal medicament with three calcium chelators, ethylenediaminetetraacetic acid, citric acid, and chitosan from root canals: An in vitro cone beam computed tomography volumetric analysis
AIM This study compared the amount of aqueous-based and oil-based calcium hydroxide remaining in the canal, after removal with two different chelators 17% EDTA, 20% Citric acid and 0.2% Chitosan in combination with ultrasonic agitation. METHODS AND MATERIAL Cleaning and shaping of root canals of 28 mandibular premolar was done and canals were filled either with Metapex or Ca(OH)2 mixed with d...
متن کاملResearch Paper: Comparison efficacy of calcium hydroxide removal by Revo-s, Protaper Rotary file from root canal
Abstract Introduction: The aim of this study was to evaluate the efficacy of two rotary instrument systems (ProTaper and Revo-s File) in removing calcium hydroxide residues from root canal walls Materials and Methods:Thirty human maxillary incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl,and filled with a calcium hydroxide intracanal dr...
متن کاملInvestigating Root Canal Number and Morphology of Mandibular Anterior Teeth Using Cone Beam Computed Tomography
Background and purpose: Root therapy will be successful if it is done based on a correct diagnosis and appropriate treatment plan with the knowledge of morphology and tooth anatomy, debridement, disinfection, and obturation of the entire root canal system. This study aimed to investigate the number and morphology of canals in root canals mandibular anterior using cone beam computed tomography (...
متن کاملComparison of transportation and centering ability using RECIPROC and iRace: A cone-beam computed tomography study
BACKGROUND AND AIM: Root canal treatment, especially in curved and constricted root canals, can be very difficult and time consuming. Several investigations have compared the reciprocating and full sequence motions in terms of shaping ability. The purpose of the present study was to compare the root canal transportation and centering ability of RECIPROC and iRace using cone-beam computed tomogr...
متن کامل