Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents.
نویسندگان
چکیده
OBJECTIVES This study sought to evaluate the clinical, procedural, preinterventional and postinterventional quantitative coronary angiographic (QCA) and intravascular ultrasound (IVUS) predictors of restenosis after Palmaz-Schatz stent placement. BACKGROUND Although Palmaz-Schatz stent placement reduces restenosis compared with balloon angioplasty, in-stent restenosis remains a major clinical problem. METHODS QCA and IVUS studies were performed before and after intervention (after stent placement and high pressure adjunct balloon angioplasty) in 382 lesions in 291 patients treated with 476 Palmaz-Schatz stents for whom follow-up QCA data were available 5.5 +/- 4.8 months (mean +/- SD) later. Univariate and multivariate predictors of QCA restenosis (> or = 50% diameter stenosis at follow-up, follow-up percent diameter stenosis [DS] and follow-up minimal lumen diameter [MLD]) were determined. RESULTS Three variables were the most consistent predictors of the follow-up angiographic findings: ostial lesion location, IVUS preinterventional lesion site plaque burden (plaque/total arterial area) and IVUS assessment of final lumen dimensions (whether final lumen area or final MLD). All three variables predicted both the primary (binary restenosis) and secondary (follow-up MLD and follow-up DS) end points. In addition, a number of variables predicted one or more but not all the end points: 1) restenosis (IVUS preinterventional lumen and arterial area); 2) follow-up DS (QCA lesion length); and 3) follow-up MLD (QCA lesion length and preinterventional MLD and DS and IVUS preinterventional lumen and arterial area). CONCLUSIONS Ostial lesion location and IVUS preinterventional plaque burden and postinterventional lumen dimensions were the most consistent predictors of angiographic in-stent restenosis.
منابع مشابه
Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.
AIMS Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS Angiographic and intravascular ul...
متن کاملBenefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents.
OBJECTIVES This study was designed to evaluate the changes in intrastent and angiographic dimensions when intravascular ultrasound imaging is used to direct the deployment of balloon-expandable Palmaz-Schatz stents in coronary arteries and saphenous vein grafts. BACKGROUND Intravascular ultrasound provides more information than angiography in the imaging of intravascular structures. Previous ...
متن کاملSmall stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.
OBJECTIVES The purpose of this study was to use volumetric intravascular ultrasound analysis of Palmaz-Schatz stents to assess the in-stent restenotic process. BACKGROUND By reducing lesion elastic recoil and chronic arterial remodeling, stents improve the long-term results of coronary angioplasty. However, stents are prone to the development of neointimal hyperplasia. Angiographic studies of...
متن کاملAngiographic and intravascular ultrasound predictors of in-stent restenosis.
OBJECTIVES This study was performed to determine predictors of in-stent restenosis from a high volume, single-center practice. BACKGROUND Intracoronary stents have been shown to reduce the restenosis rate as compared with balloon angioplasty, but in-stent restenosis continues to be an important clinical problem. METHODS Between April 1993 and March 1997, 1,706 patients with 2,343 lesions we...
متن کاملPredictors of restenosis after coronary stent implantation.
OBJECTIVES We sought to determine predictors of restenosis after coronary stenting (CS) in a consecutive series of patients. BACKGROUND Although stenting in highly selected patient groups reduces restenosis, the results of stenting in a heterogeneous patient group and the effects of clinical and procedural factors on stent restenosis are currently unclear. METHODS We analyzed the 6-month an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 31 1 شماره
صفحات -
تاریخ انتشار 1998