A bench study of 2 ventilator circuits during helmet noninvasive ventilation.

نویسندگان

  • Giuliano Ferrone
  • Flora Cipriani
  • Giorgia Spinazzola
  • Olimpia Festa
  • Andrea Arcangeli
  • Rodolfo Proietti
  • Massimo Antonelli
  • Giorgio Conti
  • Roberta Costa
چکیده

OBJECTIVE To compare helmet noninvasive ventilation (NIV), in terms of patient-ventilator interaction and performance, using 2 different circuits for connection: a double tube circuit (with one inspiratory and one expiratory line) and a standard circuit (a Y-piece connected only to one side of the helmet, closing the other side). METHODS A manikin, connected to a test lung set at 2 breathing frequencies (20 and 30 breaths/min), was ventilated in pressure support ventilation (PSV) mode with 2 different settings, randomly applied, of the ratio of pressurization time to expiratory trigger time (T(press)/T(exp-trigger)) 50%/25%, default setting, and T(press)/T(exp-trigger) 80%/60%, fast setting, through a helmet. The helmet was connected to the ventilator randomly with the double and the standard circuit. We measured inspiratory trigger delay (T(insp-delay)), expiratory trigger delay (T(exp-delay)), T(press)), time of synchrony (T(synch)), trigger pressure drop, inspiratory pressure-time product (PTP), PTP at 300 ms and 500 ms, and PTP at 500 ms expressed as percentage of an ideal PTP500 (PTP500 index). RESULTS At both breathing frequencies and ventilator settings, helmet NIV with the double tube circuit showed better patient-ventilator interaction, with shorter T(insp-delay), T(exp-delay), and T(press); longer T(synch); and higher PTP300, PTP500, and PTP500 index (all P < .01). CONCLUSIONS The double tube circuit had significantly better patient-ventilator interaction and a lower rate of wasted effort at 30 breaths/min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study.

BACKGROUND In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive resp...

متن کامل

Effectiveness of mask and helmet interfaces to deliver noninvasive ventilation in a human model of resistive breathing.

The helmet, a transparent latex-free polyvinyl chloride cylinder linked by a metallic ring to a soft collar that seals the helmet around the neck, has been recently proposed as an effective alternative to conventional face mask to deliver pressure support ventilation (PSV) during noninvasive ventilation in patients with acute respiratory failure. We tested the hypothesis that mechanical charact...

متن کامل

Case Reports Helmet Noninvasive Ventilation for Weaning From Mechanical Ventilation

We saw a patient who presented with carbon dioxide narcosis and acute respiratory failure due to an exacerbation of chronic obstructive pulmonary disease. We intubated and 12 hours later he had recovered consciousness and could cooperate with noninvasive ventilation, at which point we extubated and used a helmet to provide noninvasive positive-pressure ventilation in assist/control mode, and th...

متن کامل

Helmet noninvasive ventilation for weaning from mechanical ventilation.

We saw a patient who presented with carbon dioxide narcosis and acute respiratory failure due to an exacerbation of chronic obstructive pulmonary disease. We intubated and 12 hours later he had recovered consciousness and could cooperate with noninvasive ventilation, at which point we extubated and used a helmet to provide noninvasive positive-pressure ventilation in assist/control mode, and th...

متن کامل

Complications following pulmonary lobectomy: the role of helmet noninvasive ventilation.

We read with great interest the paper by Barbagallo et al on prophylactic use of helmet CPAP after pulmonary lobectomy: a randomized control trial.1 Noninvasive ventilation (NIV) is a type of ventilation that does not require placement of an artificial airway. Selection of ventilation interfaces and the type of ventilator are the most important and influencing factors. Different types of interf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 9  شماره 

صفحات  -

تاریخ انتشار 2013