Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT.
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to investigate the accuracy and reproducibility of results acquired with computer-aided volumetry software during MDCT of pulmonary nodules exhibiting ground-glass opacity. MATERIALS AND METHODS To evaluate the accuracy of computer-aided volumetry software, we performed thin-section helical CT of a chest phantom that included simulated 3-, 5-, 8-, 10-, and 12-mm-diameter ground-glass opacity nodules with attenuation of -800, -630, and -450 HU. Three radiologists measured the volume of the nodules and calculated the relative volume measurement error, which was defined as follows: (measured nodule volume minus assumed nodule volume / assumed nodule volume) x 100. Two radiologists performed two independent measurements of 59 nodules in humans. Intraobserver and interobserver agreement was evaluated with Bland-Altman methods. RESULTS The relative volume measurement error for simulated ground-glass opacity nodules measuring 3 mm ranged from 51.1% to 85.2% and for nodules measuring 5 mm or more in diameter ranged from -4.1% to 7.1%. In the clinical study, for intraobserver agreement, the 95% limits of agreement were -14.9% and -13.7% and -16.6% to 15.7% for observers A and B. For interobserver agreement, these values were -16.3% to 23.7% for nodules 8 mm in diameter or larger. CONCLUSION With computer-aided volumetry of ground-glass opacity nodules, the relative volume measurement error was small for nodules 5 mm in diameter or larger. Intraobserver and interobserver agreement was relatively high for nodules 8 mm in diameter or larger.
منابع مشابه
Solitary ground-glass opacity nodules of stage IA pulmonary adenocarcinoma: combination of 18F-FDG PET/CT and high-resolution computed tomography features to predict invasive adenocarcinoma
To investigate the performance of combined 18F-FDG Positron Emission Tomography/Computed Tomography with high-resolution CT for differentiating invasive adenocarcinoma from adenocarcinoma in situ (pre-invasive lesion) or minimally invasive adenocarcinoma in stage IA lung cancer patients with solitary ground-glass opacity nodules. This retrospective study enrolled 58 consecutive stage IA pulmona...
متن کاملResearch on a Pulmonary Nodule Segmentation Method Combining Fast Self-Adaptive FCM and Classification
The key problem of computer-aided diagnosis (CAD) of lung cancer is to segment pathologically changed tissues fast and accurately. As pulmonary nodules are potential manifestation of lung cancer, we propose a fast and self-adaptive pulmonary nodules segmentation method based on a combination of FCM clustering and classification learning. The enhanced spatial function considers contributions to ...
متن کاملGround-glass Opacity Detection Based on Correlation between Successive Slice Images
Medical imaging systems such as computed tomography, magnetic resonance imaging provided a high resolution image for powerful diagnostic tool in visual inspection fields by physician. Especially MDCT image can be used to obtain detailed images of the pulmonary anatomy, including pulmonary diseases such as the pulmonary nodules, the pulmonary vein, etc. In the medical image processing technique,...
متن کاملEvaluation of pure ground glass pulmonary nodule: a case report
A pulmonary nodule is a single, nearly spherical, well-circumscribed pulmonary opacity up to 30 mm in diameter and surrounded by aerated lung tissue. In radiographs, pulmonary nodules may appear as solid, completely obscuring the lung parenchyma, or as subsolid, not completely obscuring adjacent tissues. A subsolid pulmonary nodule may be further subclassified as a pure ground glass nodule (pGG...
متن کاملSilicosis due to Denim Sandblasting in Young People: MDCT Findings.
OBJECTIVE Occupational lung disease due to silica dust is one of the most common work-related injuries. In denim sandblasting, workers are exposed to silica that may cause immediate mortality, especially in young people. The aim of this study was to assess the multidetector computed tomography (MDCT) findings of silicosis in denim sandblasters and to better define the role of MDCT in the early ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 194 2 شماره
صفحات -
تاریخ انتشار 2010