Assessment of antibiotic susceptibility of Legionella pneumophila isolated from water systems in Poland.

نویسندگان

  • Agnieszka Sikora
  • Iwona Gładysz
  • Maria Kozioł-Montewka
  • Małgorzata Wójtowicz-Bobin
  • Tomasz Stańczak
  • Renata Matuszewska
  • Bożena Krogulska
چکیده

INTRODUCTION AND OBJECTIVE Several studies have reported therapy failures in patients with legionnaires'disease; however, antimicrobial resistance of clinical and environmental isolates of Legionella spp. has not yet been documented. Routine susceptibility testing of Legionella spp. is not recommended because of difficulties in determining standard minimal inhibitory concentration values. The purpose of this study was to analyze the antimicrobial susceptibility of Legionella pneumophila. strains isolated from a water supply system. MATERIALS AND METHOD Twenty-eight isolates of L. pneumophila (16 - L. pneumophila SG 1, 12 - L. pneumophila SG 2-14) obtained from water systems in public buildings in Poland were tested. Susceptibility testing was performed using the E-test method. The tested antibiotic were azithromycin, ciprofloxacin, and rifampicin. The medium used for the susceptibility testing was BCYE-, a special medium for Legionella cultivation. RESULTS Among the tested strains, L. pneumophila was the only one resistant to azithromycin. It was a strain of L. pneumophila SG 2-14 isolated from the water system in a sanitorium. All isolates were found to be sensitive to ciprofloxacin and rifampicin. However, the azithromycin-resistant strain exhibited higher ciprofloxacin and rifampicin MIC (1.5 μg/ml, and 0.19 μg/ml, respectively). The MIC50 for azithromycin, ciprofloxacin, and rifampicin were 0,032, 0,125, and 0,003 μg/ml, respectively. The MIC90 for azithromycin, ciprofloxacin, and rifampicin were 0,032, 0,125, and 0,003 μg/ml, respectively. CONCLUSIONS Azithromycin resistance was found in one strain of L. pneumophila SG 2-14, but the resistance mechanism is unknown and needs further study. It is possible that therapeutic failures in Legionnaires' disease may be associated with bacterial resistance which should be taken into account. The antibiotic sensitivity testing described in this study could be helpful in detecting the resistance of clinical L. pneumophila isolates. Ciprofloxacin and rifampicin have good in vitro activity against environmental L. pneumophila SG 1 and SG 2-14 in Poland.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular &culture methods

Legionella pneumophila, the causative agent of Legionnaires’ diseases (LD) is usually transmitted to humans via inhalation of aerosols from contaminated natural and manmade water sources. These organisms may become fatal especially in immunocompromised patients and LD is the one of the important disease from a public health perspective. This survey investigated the frequency of Legionella spp. ...

متن کامل

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...

متن کامل

Sequence-based typing of Legionella pneumophila strains isolated from hospital water distribution systems as a complementary element of risk assessment of legionellosis in Poland.

Many factors affect the risk of Legionella infection, such as the design, construction and maintenance of water distribution systems, the presence of individuals who may be exposed and their vulnerability to infection, and the degree of water system colonization and properties of Legionella strains. For epidemiological investigations, two properties of the Legionella strains are usually determi...

متن کامل

An Investigation of the Legionella Pneumophila Infection in Pneumonic Patients in Three Different Infections Hospital Wards in Tehran

Legionella pneumophila is one of the causative agent of pneumonia in human being. In recent years many reports has been come from different parts of world regarding infectivity of this organism. This disease occurs almost because of contamination of air conditioning systems. For the purpose of assessment of the legionella pneumophila in pneumonic patients, 200 specimen from sputum and tracheo-b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of agricultural and environmental medicine : AAEM

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2017