The Limited Streamer Tubes of the Sld *

نویسنده

  • A. C. BENVENUTI
چکیده

A large hadron calorimeter and muon tracking device using plastic streamer tubes has been constructed in the iron flux-return structure for the SLD detector at SLAC. Various studies of the operating characteristics of the streamer tubes of this system are presented. Emphasis is placed on the tracking capabilities of the device and on the optimization of the high voltage and readout electronics. Submitted to Nuclear Instruments an,d Methods A. *Work supported in part by Department of Energy (USA) contracts DE-AC02-7GER03069 (MIT), DE-AC03-76SF00515 (SLAC), and DE-AC02-76ER00881 (VW), and by the Istituto Nazionale di Fisica Nucleare (Italy).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Iron Calorimeter and Muon Identifier for Sld*

The iron flux-return structure for the SLC Large Detector (SLD) has’ been instrumented with plastic streamer tubes covering an area of about 4500 square meters, to provide muon identification plus energy measurement of hadron showers. A description is given of the production techniques used to construct this large detector system, with an emphasis on the methods by which high reliability and a ...

متن کامل

Limited Streamer Tube and Capacitor Testing for BABAR Detector

Testing of Limited Streamer Tubes (LSTs) has been conducted on the first set of LSTs meant for installation in the BABAR detector. The tubes are kept under high voltage (between 5 and 6 KV) as often as possible to ensure their durability. Three tests were conducted: signal charge, leak and radioactive source. Testing is conducted to ensure that no damage occurred during transport of the LSTs fr...

متن کامل

A layer of streamer tube detectors for the measurement of muons in the KASCADE central detector

For an improved detection of cosmic ray muons with a threshold of 2.4 GeV, the KASCADE Central Detector has been upgraded with a new detector component built of limited streamer tubes. Combined with the operation of two layers of multiwire proportional chambers they enable studies of the muonic component of extensive air showers at higher particle densities. Due to the pad readout system of the...

متن کامل

Study of Dimethyl Ether for Limited Streamer Tubes*

Position resolution and lifetime have been studied for one-atmosphere D\IE in half-inch diameter aluminum tube chambers operated in the limited streamer mode. The radial resolution was measured by timing to be CT, = 73 pm. The longitudinal resolution was measured by charge division to be < 0.3% of the wire length. No significant gain changes were seen after 12 C/cm. Submitted to Nuclear Instrum...

متن کامل

Limited Streamer Tubes for the Babar Instrumented Flux Return Upgrade

Starting from the very beginning of their operation the efficiency of the RPC chambers in the BaBar Instrumented Flux Return (IFR) has suffered serious degradation. After intensive investigation, various remediation efforts had been carried out, but without success. As a result the BaBar collaboration decided to replace the dying barrel RPC chambers about two years ago. To study the feasibility...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1989