Anterior segment OCT imaging after femtosecond laser cataract surgery.
نویسندگان
چکیده
PURPOSE To report the anterior segment imaging characteristics after femtosecond laser assisted cataract surgery. METHODS Cataract surgery was performed with the LenSx femtosecond laser (Alcon-LenSx Inc., Aliso Viejo, CA) in 40 eyes of 40 patients. The laser was programmed to perform a 4.5-mm capsulorhexis, a cross-pattern fragmentation of the nucleus, a 2.8-mm main incision, and a 1.0-mm side-port incision. The anterior segment was then analyzed using the Visante OCT anterior segment program (Zeiss-Meditec AG, Jena, Germany). RESULTS The preoperatively set treatment parameters correlated well with the achieved results. For the capsulorhexis, the femtosecond laser cut was programmed to start 350 μm behind the anterior lens capsule and OCT measured 377 ± 55.3 μm. Nucleus fragmentation was programmed to start 750 μm in front of the posterior capsule and end 550 μm behind the anterior capsule, and OCT measured 794 ± 111 and 568 ± 147 μm, respectively. The diameter of the capsulorhexis measured by OCT was 4.54 ± 0.2 mm, compared to the 4.5 mm programmed. CONCLUSIONS Anterior segment OCT imaging was able to detect the tissue changes within the lens after femtosecond laser capsulorhexis and nucleus fragmentation. The measured values correlated well with the planned treatment parameters.
منابع مشابه
Update and clinical utility of the LenSx femtosecond laser in cataract surgery
The introduction of femtosecond lasers to cataract surgery has been the major disruptive technology introduced into ophthalmic surgery in the last decade. Femtosecond laser cataract surgery (FLACS) integrates high-resolution anterior segment imaging with a femtosecond laser allowing key steps of cataract surgery to be performed with computer-guided laser accuracy, precision, and reproducibility...
متن کاملCorneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography.
PURPOSE To assess and compare the morphology of laser in situ keratomileusis flaps (LASIK) created by a 60 kHz femtosecond laser and a mechanical microkeratome. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS Anterior segment optical coherence tomography (AS-OCT) (Visante) was used to assess 1 week postoperatively the morphology of...
متن کاملDescemet membrane detachment in femtosecond laser-assisted cataract surgery: a case report
BACKGROUND Femtosecond laser-assisted cataract surgery (FLACS) has grown in popularity among ophthalmologists as a novel technique. However, descemet membrane detachment (DMD) began to be found as the complication after FLACS. We report a case of serious DMD following FLACS due to the inappropriate incision design. CASE PRESENTATION An 85-year-old man with apparent cornea arcus senilis underw...
متن کاملIn vivo structural characteristics of the femtosecond LASIK-induced opaque bubble layers with ultrahigh-resolution SD-OCT.
The authors report in vivo morphology of opaque bubble layers with ultrahigh-resolution anterior-segment optical coherence tomography (UHR-OCT) in 3 patients. Two patients were operated on with a 30-kHz IntraLase femtosecond laser (Abbott Medical Optics, Abbott Park, IL) and one patient was operated on with a 500-kHz VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). UHR-OCT images ...
متن کاملDistortions of iris and anterior lens capsule OCT images by ICRS.
Intracorneal ring segments (ICRS) have been used in patients with keratoconus for slowing keratoconic progression and delaying keratoplasty.1,2 However, we experienced anterior optical coherence tomography (OCT) image distortion of the iris in patients with ICRS insertion by chance. Some femtosecond laser cataract surgery systems use OCT images of the cornea, anterior lens capsule, and nucleus ...