Comparison of Abbott LCx Chlamydia trachomatis assay with Gen-Probe PACE2 and culture.

نویسندگان

  • D C Young
  • S Craft
  • M C Day
  • B Davis
  • E Hartwell
  • S Tong
چکیده

In this study the LCx assay (a nucleic acid amplification assay) for Chlamydia trachomatis in endocervical samples was compared with the Gen-Probe PACE2 assay (a nucleic acid probe assay) for endocervical samples, and with endocervical culture. In addition, the efficacy of the LCx assay was determined for midstream clean-catch urine samples because it is often necessary to obtain such a sample for routine urine culture and it is simpler to collect only a single sample without also collecting a first-void urine for LCx. Endocervical specimens from 205 patients were tested for C. trachomatis via LCx and PACE2. Of these patients, 203 were tested by culture. Midstream clean-catch urine samples from 75 of these patients were tested by LCx. The sensitivities and specificities for these assays, after discrepant analysis, were 100 and 98.9% for LCx of endocervical samples, 52.4 and 100% for PACE2; and 71.4 and 100% for culture. The sensitivity/specificity of LCx for midstream clean-catch urines was 66.7/98.5%. The apparent prevalence of C. trachomatis in our population was 10.2%. These data indicate that among the methods tested, LCx of endocervical samples had the highest sensitivity for C. trachomatis in this population. The sensitivity of the urine LCx assay using midstream clean-catch collected urines was considerably less than that reported in other studies that used first-void urines but was higher than that of PACE2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three commercially available amplification assays, AMP CT, LCx, and COBAS AMPLICOR, for detection of Chlamydia trachomatis in first-void urine.

We compared the Gen-Probe transcription-mediated amplification assay (AMP CT), the Abbott LCx assay, and the Roche COBAS AMPLICOR assay for the detection of Chlamydia trachomatis in a mixed population in urine samples. First-void urine, urethral specimens, and cervical specimens in females were obtained from 1,000 patients (544 males and 456 females) visiting the outpatient sexually transmitted...

متن کامل

Comparison of the PACE 2 assay, two amplification assays, and Clearview EIA for detection of Chlamydia trachomatis in female endocervical and urine specimens.

Screening for sexually transmitted diseases (STDs) in a greater proportion of sexually active patients has become an accepted protocol by most health care providers. The purpose of this study was to compare the current test methods for detection of Chlamydia trachomatis used at the University of South Alabama, the PACE 2 assay (Gen-Probe) and the Clearview EIA (Wampole Laboratories), with two a...

متن کامل

Comparison of the APTIMA CT and GC assays with the APTIMA combo 2 assay, the Abbott LCx assay, and direct fluorescent-antibody and culture assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

The Gen-Probe APTIMA Combo 2 (AC2) is a Food and Drug Administration-cleared nucleic acid amplification test (NAAT) for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae from urine and urogenital swab specimens. The Centers for Disease Control and Prevention have recommended confirmation of positive NAAT results in low-prevalence populations. APTIMA CT (ACT) and APTIMA GC (AGC) a...

متن کامل

Comparison of the Abbott RealTime CT new formulation assay with two other commercial assays for detection of wild-type and new variant strains of Chlamydia trachomatis.

In an analytical-method comparison study of clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR), consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis, was compared both with version 2 of the Roche Cobas TaqMan CT assay, comprising a duplex PCR for a target in the cryptic plasmid and the omp1 gene, and with the Gen-...

متن کامل

Comparison of three nucleic acid amplification tests for detection of Chlamydia trachomatis in urine specimens.

Traditionally, culture and immunoassays have been performed for the detection of sexually transmitted diseases, including Chlamydia trachomatis. However, these assays may often require invasive specimen collection methods, such as female cervical and male urethral swabs. Recently, nucleic acid amplification tests (NAATs) have been approved for testing for the presence of C. trachomatis in urine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infectious Diseases in Obstetrics and Gynecology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2000