Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: experimental and theoretical dependence on sample properties.
نویسندگان
چکیده
The RF B(1) distribution was studied, theoretically and experimentally, in phantoms and in the head of volunteers using a 3 T MRI system equipped with a birdcage coil. Agreement between numerical simulation and experiment demonstrates that B(1) distortion at high field can be explained with 3D full-Maxwell calculations. It was found that the B(1) distribution in the transverse plane is strongly dependent on the dielectric properties of the sample. We show that this is a consequence of RF penetration effects combined with RF standing wave effects. In contrast, along the birdcage coil z-axis the B(1) distribution is determined mainly by the coil geometry. In the transverse plane, the region of B(1) uniformity (within 10% of the maximum) was 15 cm with oil, 6 cm with distilled water, 11 cm with saline, and 10 cm in the head. Along z the B(1) uniformity was 9 cm with phantoms and 7 cm in the head.
منابع مشابه
BI Field Plots for a 3 Tesla Birdcage Coil: Concordance of Experimental and Theoretical Results
To compare the measured and the simulated radio frequency Bt distribution in cylindrical phantoms and in the head of healthy volunteers at 128 MHz. The experimental data were obtained with a 3 Tesla MRI research system equipped with a blrdcage coil. The simulated data were obtained with the Finite Difference Time Domain (FDTD) method of calculation for electromagnetics. MATERIAL AND METHODS the...
متن کاملDesign and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T
This work describes the study of coil for Magnetic Resonance Imaging (MRI) application. Concretely, the principal objective is the design of a birdcage coil (RF coil) to use in a 7 Tesla scanner. More strength field has a better SNR and increased chemical shift effects, improving spectral fat suppression and spectroscopy. Moreover, a better SNR increases the spatial resolution or reduces the im...
متن کاملMagnetic Field Homogeneity of Birdcage Coil for 4T MRI System with No Lumped Circuit Elements
In recent years, magnetic resonance imaging (MRI) systems that operate up to under 3 T are being used in clinical practice in Japan. In order to achieve the requirements of higher image quality and shorter imaging times, devices that utilize high magnetic fields (> 3 T) and high power electromagnetic (EM) wave pulses have been developed. The rise of the static magnetic field is proportional to ...
متن کاملThe intrinsic magnetic field symmetries of the spiral birdcage coil
INTRODUCTION Transmit array spatial encoding (TRASE) is a novel MRI technique that utilizes B1-field phase gradients as the means for traversing k-space [1-3]. This method allows MRI to be performed without the usual application of B0-field amplitude gradients, thereby possibly eliminating the equipment, complexity, power consumption and acoustic noise associated with traditional static-field g...
متن کاملRADIOFREQUENCY COIL DESIGN AND APPLICATION TO MAGNETIC RESONANCE IMAGING AND CONTROL OF MICRO-BEADS by
Radio Frequency coil development, one component of a functioning magnetic resonance imaging (MRI) system, has evolved since the beginning of MRI into a very diverse area. Today for example, transmit and receive coils, volume and surface coils, and single channel and multiple channel coils are all included. Coils are created to fit the particular needs of specific research purposes, taking into ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 46 2 شماره
صفحات -
تاریخ انتشار 2001