An accurate and precise liquid chromatographic method was developed for the simultaneous estimation of telmisartan and metoprolol succinate in tablets. The chromatographic analysis was performed on Nucleosil C18 Column (250*4.6mm 5μ particle size) with mobile phase consisting of acetonitrile and potassium di-hydrogen orthophosphate buffer (pH2.8) in the ratio 60:40v/v, at a flow rate of 0.8ml/min and eluents monitored at 220nm. The retention time for telmisartan was found to be 3.392 and for metoprolol succinate it was found to be 5.221 minutes. The proposed method is simple, accurate and precise and could be successfully employed in routine quality control for the simultaneous estimation of telmisartan and metoprolol succinate in tablets.
منابع مشابه
Absorbance correction method for estimation of telmisartan and metoprolol succinate in combined tablet dosage forms
AIM AND BACKGROUND The present manuscript describes simple, sensitive, rapid, accurate, precise and economical spectrophotometric method for the simultaneous determination of telmisartan and metoprolol succinate in combined tablet dosage form. MATERIALS AND METHODS The method is based on the absorbance correction equations for analysis of both the drugs using methanol as solvent. Telmisartan ...
متن کاملDevelopment and validation of a stability indicating RP-HPLC method for simultaneous estimation of Olmesartan Medoxomil and Metoprolol Succinate in pharmaceutical dosage form
AIM AND BACKGROUND A simple, rapid, precise and isocratic RP-HPLC (Reverse Phase High Performance Liquid Chromatography) method is aimed to develop for the simultaneous estimation of Olmesartan Medoxomil and Metoprolol Succinate in bulk drug and pharmaceutical dosage form. MATERIALS AND METHODS The quantification is carried out using YMC-Pack CN (250 × 4.6 mm, 5.0 μm) column and the mobile ph...
متن کاملDevelopment of Reverse-Phase HPLC Method for Simultaneous Analysis of Metoprolol Succinate and Hydrochlorothiazide in a Tablet Formulation
Purpose: To develop a simple, sensitive and rapid reverse phase HPLC method for the simultaneous analysis of metoprolol succinate and hydrochlorothiazide in a solid dosage form. Methods: The drugs were analysed by a reverse phase C-18 column using 50mM di-sodium hydrogen phosphate:methanol:acetonitrile in a ratio of 525:225:250 as mobile phase. The flow rate was 1 ml/min and the compounds were ...
متن کاملSimultaneous Determination of Sartans by High Performance Liquid Chromatography with Ultra Violet Detection
Objective: A high performance liquid chromatographic method with ultra violet detection for simultaneous analysis of three sartans (Valsartan, Irbesartan and Telmisartan) has been developed for quality control. Method and Results: Isocratic elution on a LiChrospher C18 column (250 × 4 mm, particle size 5 μm) at the temperature 30oC with a mobile phase consisting of 10mM phosphate buffer: aceton...
متن کاملInfluence of Formulation Factors and Compression Force on Release Profile of Sustained Release Metoprolol Tablets using Compritol® 888ATO as Lipid Excipient
Tablets containing metoprolol succinate and Compritol(®) 888ATO in the ratio of 1:2 yielded the desired sustained release profile in phosphate buffer pH 6.8 when evaluated using USP type II paddle apparatus and was selected as the optimized formulation. Robustness of optimized formulation was assessed by studying the effect of factors like varying source of metoprolol succinate and Compritol(®)...
متن کامل