SQUID Systems for Geophysical Time Domain Electromagnetics (TEM) at IPHT Jena

نویسندگان

  • Andreas Chwala
  • Ronny Stolz
  • Matthias Schmelz
  • Vyacheslav Zakosarenko
  • Matthias Meyer
  • Hans-Georg Meyer
چکیده

Forty years after the first application of Superconducting Quantum Interference Devices (SQUIDs) [1], [2] for geophysical purposes, they have recently become a valued tool for mineral exploration. One of the most common applications is time domain (or transient) electromagnetics (TEM), an active method, where the inductive response from the ground to a changing current (mostly rectangular) in a loop on the surface is measured. After the current in the transmitter coil is switched, eddy currents are excited in the ground, which decay in a manner dependent on the conductivity of the underlying geologic structure. The resulting secondary magnetic field at the surface is measured during the off-time by a receiver coil (induced voltage) or by a magnetometer (e.g. SQUID or fluxgate). The recorded transient signal quality is improved by stacking positive and negative decays. Alternatively, the TEM results can be inverted and give the electric conductivity of the ground over depth. Since SQUIDs measure the magnetic field with high sensitivity and a constant frequency transfer function, they show a superior performance compared to conventional induction coils, especially in the presence of strong conductors. As the primary field, and especially its slew rate, are quite large, SQUID systems need to have a large slew rate and dynamic range. Any flux jump would make the use of standard stacking algorithms impossible. IPHT and Supracon are developing and producing SQUID systems based on low temperature superconductors (LTS, in our case niobium), which are now state-of-the-art. Due to the large demand, we are additionally supplying systems with high temperature superconductors (HTS, in our case YBCO). While the low temperature SQUID systems have a better performance (noise and slew rate), the high temperature SQUID systems are easier to handle in the field. The superior performance of SQUIDs compared to induction coils is the most important factor for the detection of good conductors at large depth or ore bodies underneath conductive overburden. key words: SQUID, magnetometer, geophysical exploration, time domain electromagnetics

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hydrogeophysical methods for analyzing aquifer storage and recovery systems.

Hydrogeophysical methods are presented that support the siting and monitoring of aquifer storage and recovery (ASR) systems. These methods are presented as numerical simulations in the context of a proposed ASR experiment in Kuwait, although the techniques are applicable to numerous ASR projects. Bulk geophysical properties are calculated directly from ASR flow and solute transport simulations ...

متن کامل

Performance Metrics for State-of-the-Art Airborne Magnetic and Electromagnetic Systems for Mapping and Detection of Unexploded Ordnance

Over the past decade, notable progress has been made in the performance of airborne geophysical systems for mapping and detection of unexploded ordnance in terrestrial and shallow marine environments. For magnetometer systems, the most significant improvements include development of denser magnetometer arrays and vertical gradiometer configurations. In prototype analyses and recent Environmenta...

متن کامل

Superconductive Digital Magnetometers with Single-Flux-Quantum Electronics

Superconducting Quantum Interference Devices (SQUIDs) are known to be the most sensitive magnetometers, used in a wide range of applications like biomagnetism, geomagnetism, Non Destructive Evaluation (NDE), metrology or fundamental science. For all these applications, the SQUID sensor is used in analog mode and associated with a carefully designed room-temperature control and/or feedback elect...

متن کامل

Instant Focal Series in High Resolution Structured Illumination Microscopy

Aurélie Jost, Sara Abrahamsson and Rainer Heintzmann Institute of Physical Chemistry, Abbe Center of Photonics, Friedrich-SchillerUniversity Jena, Helmholtzweg 4, 07743 Jena, Germany Leibniz Institute of Photonic Technology, Albert-Einstein Str. 9, 07745 Jena, Germany Leon Levy Fellow, The Rockefeller University, Center for Neural Circuits and Behavior, New York, USA King’s College London, Rand...

متن کامل

Noise-induced quantum coherence and persistent Rabi oscillations in a Josephson flux qubit

A. N. Omelyanchouk,1 S. Savel’ev,2,3 A. M. Zagoskin,2,3 E. Il’ichev,4 and Franco Nori3,5 1B.Verkin Institute for Low Temperature Physics and Engineering, 61103 Kharkov, Ukraine 2Department of Physics, Loughborough University, Leicestershire LE11 3TU, United Kingdom 3Digital Materials Laboratory, Advanced Science Institute, RIKEN, Wako-shi, Saitama 351-0198, Japan 4Institute of Photonic Technolo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEICE Transactions

دوره 98-C  شماره 

صفحات  -

تاریخ انتشار 2015