Evaluation of exhalation valves.
نویسندگان
چکیده
Certification tests currently employed by some industrialized nations to certify respirators require that when challenged with air flow at a constant suction head of 25 mmH2O, the leakage into the facepiece from the exhalation valve(s) should not exceed 30 ml min(-1). However, the test alone might not reflect the leakage rate under different levels of vacuum. To study the characteristics of leakage through exhalation valves, a leakage meter was built to measure the leakage rate of four brands of exhalation valves. Seven valves of each brand were tested for leakage rate at pressure drops ranging from 15 to 45 mmH2O (or extended to 75 mmH2O for some valves). Two types of leaks, i.e. fiber insertion and arch dent on the valve seat, were used to investigate the effect of leak shape on the characteristic leak flow as a function of pressure drop. A leakage data point represented a mean value of five measurements. The results showed that the leakage rate could increase or decrease with increasing pressure drop inside the respirators, indicating that the current method of conducting leakage tests, at a constant suction head of 25 mmH2O, does not guarantee better protection than when the respirators are used at a lower suction head. Moreover, based on the sample valves tested in this study, it was found that valve leakage was mostly caused by defects in the valve seats. Both fiber-insertion and arch-dent leaks had either increasing or decreasing characteristic curves, depending on the size of the leak and the material of the valve membrane.
منابع مشابه
Bench study on active exhalation valve performance.
BACKGROUND Ventilator exhalation-valve performance during the expiratory phase has been studied in depth. An active exhalation valve uses servo-control technology that allows gas to be released from the exhalation valve during the inspiratory phase if the patient makes an expiratory effort. We conducted a bench study of active exhalation valve response to expiratory effort during the inspirator...
متن کاملEvaluation of radon exhalation rate and excessive lifetime cancer risk in Dumpsites in Ondo city Southwestern Nigeria
Background: Ondo city in Ondo State Nigeria includes Ondo East and West could be described as a research city due to antecedent number of research institutes. Materials and Methods: Dose due to radioactivity content of soil samples from sixteen waste dump sites in Ondo, Southwestern Nigeria was determined using gamma-ray spectrometer in order to evaluate the radiation hazard health profile and ...
متن کاملRadium and radon exhalation studies of soil
Background: Everyone is exposed to radon because it is present everywhere with varying concentrations. Radon and its progeny are well established as lung carcinogenic. Materials and Methods: Track etch technique using LR-115 plastic track detectors has been used to measure the effective radium content and radon exhalation rates in soil samples collected from urban area of Etah district...
متن کاملEffects of condensate in the exhalation limb of neonatal circuits on airway pressure during bubble CPAP.
BACKGROUND Bubble CPAP is frequently used in spontaneously breathing infants with lung disease. Often bubble CPAP systems lack pressure alarms and pressure-release valves. We observed a large volume of condensate in the exhalation limb of a patient circuit and conducted a series of experiments to test the hypothesis that accumulated condensate could affect delivered pressures. METHODS An anat...
متن کاملA proximal system for positive end-expiratory pressure (PEEP) and continuous positive airway pressure (CPAP).
A proximal positive end-expiratory pressure (PEEP) and continuous positive airway pressure (CPAP) system was constructed by the simple addition of a venturi T-piece proximal to the exhalation limb of a breathing circuit. The level of PEEP or CPAP was determined by the amount of flow powering the venturi. This system can provide positive pressure in excess of 40 cm H2O without the need for check...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 49 7 شماره
صفحات -
تاریخ انتشار 2005