Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts
نویسندگان
چکیده
The purpose of this in vitro study was to compare the precision of fit of substructures milled from semi-sintered zirconia blocks, fabricated with two different fabrication concepts. Three-unit, posterior fixed dental prostheses (FDP) were fabricated for standardized dies (n = 10) with the laboratory Computer Aided Design (CAD)/Computer Aided Manufacturing (CAM) system Cercon® Brain (Brain) and the centralized CAD/CAM system Compartis Integrated Systems (Compartis). After cementation to the dies, the FDP were embedded and sectioned. Four cross-sections were made of each abutment tooth, and marginal and internal fit were evaluated under an optical microscope. A one-way analysis of variance (ANOVA) was used to compare data (α = 0.05). Mean gap dimensions at the marginal opening for Brain and Compartis were 56.0 (±34.5) μm and 51.7 (±45.2) μm, respectively. Mean internal gap dimensions of 62.8 (±37.5) μm to 164.6 (±33.4) μm were measured depending on the measurement location and the fabrication concept. Mean marginal openings and internal adaptations were not significantly different for both systems. Three out of four measurement locations showed significantly different cement gaps. Within the limitations of this study, the results suggest that the accuracy of both investigated systems is satisfactory for clinical use. The laboratory fabrication exhibited similar accuracy as the centralized manufacturing.
منابع مشابه
Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system
PURPOSE The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured b...
متن کاملGap comparison between single crown and three-unit bridge zirconia substructures
PURPOSE To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using Lava™ system...
متن کاملمقایسه گپ مارژینال فریم ورکهای زیرکونیایی متکی بر ایمپلنت دو سیستم CAD/CAM
Background and Aims: Marginal accuracy is a crucial factor influencing the clinical long-term reliability of implant-supported fixed dental prostheses (FDPs). The aim of this in vitro study was to evaluate the marginal fit of three-unit zirconia bridge frameworks fabricated using two different computer-aided design (CAD)/ computer-aided manufacturing (CAM) systems (AmannGirrbach and Zirkonzahn...
متن کاملIn vitro Evaluation of the Marginal Fit and Internal Adaptation of Zirconia and Lithium Disilicate Single Crowns: Micro-CT Comparison Between Different Manufacturing Procedures
RESEARCH ARTICLE In vitro Evaluation of the Marginal Fit and Internal Adaptation of Zirconia and Lithium Disilicate Single Crowns: Micro-CT Comparison Between Different Manufacturing Procedures Francesco Riccitiello, Massimo Amato, Renato Leone, Gianrico Spagnuolo # and Roberto Sorrentino Department of Neurosciences, Reproductive and Odontostomatological Sciences, University “Federico II” of Na...
متن کاملEffect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns.
STATEMENT OF PROBLEM Monolithic zirconia crowns fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM) have recently become a common practice for the restoration of posterior teeth. The marginal fit of monolithic zirconia crowns may be affected by different cement space parameters set in the CAD software. Information is scarce regarding the effect of cement space on th...
متن کامل