Using the same cut-off for sulfur hexafluoride and nitrogen multiple-breath washout may not be appropriate.

نویسندگان

  • Sophie Yammine
  • Nina Lenherr
  • Sylvia Nyilas
  • Florian Singer
  • Philipp Latzin
چکیده

TO THE EDITOR: We agree with all important points of the four commentaries (see Ref. 6): a) Both SF6and N2-multiplebreath washout (MBW) seem to be useful in detecting ventilation inhomogeneity in patients with cystic fibrosis (CF) and primary ciliary dyskinesia (PCD). b) There are substantial differences between those two gases, both with regards to physiological effects and gas properties. c) In contrast to N2-MBW, SF6-MBW requires a wash-in phase before the wash-out with possible consequences on results. d) Subtracting 1% tissue nitrogen contribution is clearly an over-simplification. e) Many other aspects apart from the cut-off influence comparability between gases. In this regard we like to point out that the last point (that aspects other than the cut-off also influence comparability between devices and gases) has been emphasized before by us in the Viewpoint and others (2). Most of these other aspects are independent of the underlying device, such as flow-gas misalignment or software algorithms. Recent work nicely illustrates that those inaccuracies even occur if SF6 as tracer gas and different MBW setups are used (1, 3). We therefore agree that those points urgently need to be clarified by any manufacturer of commercial MBW devices (5) or operators of in-house customized MBW setups (4). Taken together, in our Viewpoint we aimed only to show in a proof-of-principle way that in addition to the other factors also the cut-off chosen can influence comparability between N2and SF6-MBW measurements. We do not recommend accounting for tissue nitrogen by applying the simplified 1% correction. Our aim was to alert the scientific community and the manufacturers about this aspect to find acceptable solutions as soon as possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiple Breath Nitrogen Washout: A Feasible Alternative to Mass Spectrometry

BACKGROUND The lung clearance index (LCI), measured by multiple breath washout (MBW), reflects global ventilation inhomogeneity and is a sensitive marker of early cystic fibrosis (CF) lung disease. Current evidence is based on a customized mass spectrometry system that uses sulfur hexafluoride (SF6) as a tracer gas, which is not widely available. Nitrogen (N2) washout may be better suited for c...

متن کامل

Correcting for tissue nitrogen excretion in multiple breath washout measurements

Nitrogen excreted from body tissues impacts the calculation of multiple breath nitrogen washout (MBWN2) outcomes. The aim of this study was to determine the effect of tissue N2 on MBWN2 outcomes in both healthy subjects and patients with CF and to assess whether it is possible to correct for tissue N2. The contribution of tissue N2 to MBWN2 outcomes was estimated by comparing MBWN2-derived func...

متن کامل

Evaluation of the Impact of Alveolar Nitrogen Excretion on Indices Derived from Multiple Breath Nitrogen Washout

BACKGROUND A large body of evidence has now accumulated describing the advantages of multiple breath washout tests over conventional spirometry in cystic fibrosis (CF). Although the majority of studies have used exogenous sulphur hexafluoride (SF6) as the tracer gas this has also led to an increased interest in nitrogen washout tests, despite the differences between these methods. The impact of...

متن کامل

A new double-tracer gas single-breath washout to assess early cystic fibrosis lung disease.

In cystic fibrosis (CF), tests for ventilation inhomogeneity are sensitive but not established for clinical routine. We assessed feasibility of a new double-tracer gas single-breath washout (SBW) in school-aged children with CF and control subjects, and compared SBW between groups and with multiple-breath nitrogen washout (MBNW). Three SBW and MBNW were performed in 118 children (66 with CF) us...

متن کامل

Double tracer gas single-breath washout: promising for clinics or just a toy for research?

Ventilation inhomogeneity reflects the efficiency of gas transport in both central, convection-dependent and peripheral, diffusion-dependent airways. In recent years, there has been a renaissance of studies using inertgas washout to assess ventilation inhomogeneity. This trend is due to promising results of multiple-breath washout (MBW) tests in different populations with various lung diseases,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 119 12  شماره 

صفحات  -

تاریخ انتشار 2015