Design and preliminary testing of an active intramedullary nail.

نویسندگان

  • Jorge Letechipia
  • Aldo Alessi
  • Gerardo Rodríguez
  • Juan Asbun
چکیده

PURPOSE To enhance bone healing through controlled interfragmentary movements, numerous experiments have been conducted in animal models employing external fixation devices to apply mechanical stimulation to the fracture site. However, the efficacy of these fixators has been questioned. On the other hand, intramedullary nailing is a widely established clinical practice for reducing closed tibial fractures. MATERIAL AND METHODS In an effort to enhance bone healing, to overcome the disadvantages of external fixators (i.e., non-uniform linear movement), and to enhance the advantages of intramedullary nailing (i.e., reduced risk of infection), an active intramedullary nail has been designed and fabricated. Active nail will provide controlled in-situ stimulation (simultaneously axial and shear) from a selectable acceleration (0.35 to 8.17g - axial and 0.44g to 10.46 g - shear), associated to a discreet set of high-frequency values (29.82 - 172.05 Hz - axial and 29.68 to 172.13 - shear). RESULTS Five active intramedullary nails were fabricated, capable of producing average acceleration between 0.35 and 10.4 g. Acceleration is applied simultaneously by all three axes (x, y, and z), resulting in axial and shear stimulation. For each acceleration level, there are a limited number of frequencies that can be selected. For each frequency, there are a limited number of acceleration levels that can be delivered. Bone morphology produces different levels of acceleration in each axe. Acceleration levels are controlled externally only by the variable power source (1.5VDC to 6VDC). Accelerated in-vitro testing showed that the life of the device exceeded the required active period. Mechanical test showed that in case of failure of the active component, the active intramedullary nail will act as a standard nail, allowing bone healing to continue its normal course. Ex vivo experiments were conducted inserting one active intramedullary nail in two intact adult sheep tibia. Results indicate that the strain induced by the active intramedullary nail (from 18.62 με to 38.13 με) has been reported to be osteogenic. Additional experiments are required in order to statistically validate the strain that can be induced in vivo by the active intramedullary nail. Also, in vivo experiments using simple fractures of the tibial shaft need to be conducted in order to assess if effectively, applying active mechanical stimulation in situ enhances bone healing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Outcome of Femoral Shaft Fracture Fixation with Intramedullary Nail in Elderly Patient and Patients Younger than 60 Years Old

Background:   Although intramedullary nailing (IMN) is an established and accepted operative treatment for femoral shaft fracture in patients younger than 60, there is a lack of data on the results of this treatment on those over 60. The purpose of this study was to determine if the outcome of IMN for femoral shaft fracture in elderly patients is also acceptable. Particular challenges in this g...

متن کامل

Elastic Stable Intramedullary Nailing of Femoral Shaft Fracture-Experience in 48 Children

Background: Femoral shaft fractures are an incapacitating pediatric injury accounting for 1.6% of all pediatric bonyinjuries. Management of these fractures is largely directed by age, fracture pattern, associated injuries, built of the childand socioeconomic status of the family. We retrospectively evaluated the use of elastic stable intramedullary nail (ESIN)in surgical management of femoral s...

متن کامل

Treatment Outcome of Intramedullary Fixation with a Locked Rigid Nail in Humeral Shaft Fractures

  Background: The aim of this study was to determine the treatment outcome of humeral shaft fractures with a locked rigid intramedullary nail in patients indicated for surgical treatment. Methods: In this descriptive-cross sectional study, all patients were followed up for one, six, and 18 months post operatively. The Short Form Questionnaire (SF-36) and Constant Shoulder Score were applied. Re...

متن کامل

Design of a retractable intramedullary nail for the humerus.

This paper describes the design of a retractable intramedullary nail for the humerus that does not require inter-locking screws. The developed nail has a series of fins which open out from the casing to grip the medullary canal of the bone, thus securing it in position. Prototypes of the nail have been mechanically tested using static compression, dynamic compression and static torsion tests. D...

متن کامل

Treatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails

  Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista de investigacion clinica; organo del Hospital de Enfermedades de la Nutricion

دوره 66 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2014