Repeatability of airway resistance measurements made using the interrupter technique.

نویسندگان

  • E Y Chan
  • P D Bridge
  • I Dundas
  • C S Pao
  • M J R Healy
  • S A McKenzie
چکیده

BACKGROUND To be able to interpret any measurement, its repeatability should be known. This study reports the repeatability of airway resistance measurements using the interrupter technique (Rint) in children with and without respiratory symptoms. METHODS Children aged 2-10 years who were healthy, had persistent isolated cough, or who had previous wheeze were studied. On the same occasion, three Rint measurements were made 15 minutes apart, before and after placebo and salbutamol given in random order. Results from those given placebo first were analysed for within-occasion repeatability. Between-occasion repeatability measurements were made 2-20 weeks apart (median 3 weeks). RESULTS For 85 pairs of measurements before and after placebo the limits of agreement were 20% expected resistance and were unaffected by age or health status. The change in resistance following bronchodilator in one of 18 healthy children, 12 of 28 with cough, and 22 of 39 with wheeze exceeded this threshold. For between-occasion measurements the limits of agreement were 32% in 72 healthy subjects, 49% in 57 with cough, and 53% in 95 with previous wheeze. CONCLUSION The measurement of airways resistance by the interrupter technique is clinically meaningful when change following an intervention such as the administration of bronchodilator is greater than its within-occasion repeatability. Between-occasion repeatability is too poor to judge change confidently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RESPIRATORY PHYSIOLOGY Repeatability of airway resistance measurements made using the interrupter technique

Background: To be able to interpret any measurement, its repeatability should be known. This study reports the repeatability of airway resistance measurements using the interrupter technique (Rint) in children with and without respiratory symptoms. Methods: Children aged 2–10 years who were healthy, had persistent isolated cough, or who had previous wheeze were studied. On the same occasion, th...

متن کامل

Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting.

This study describes the feasibility, repeatability, and interrater reliability of the measurement of airway resistance by the interrupter technique (Rint) in children 2-5 yrs of age, and examines whether reversibility to bronchodilator can be demonstrated in wheezy children. The mean of six Rint values was taken as a measurement. If subjects could complete one measurement and then a second 15 ...

متن کامل

Evaluation of the interrupter technique in healthy, unsedated infants.

The interrupter technique may be used to monitor respiratory resistance and does not require active patient cooperation, but has yet to be applied in unsedated, spontaneously breathing infants. The aim of this study was to determine if the interrupter technique is feasible in spontaneously breathing infants and to investigate the influence of facemask types and analysis techniques on the interr...

متن کامل

Microrint pulmonary function testing in older adults with an intellectual disability.

BACKGROUND Pulmonary function testing is not feasible in many adults with intellectual disabilities, because of difficulties with understanding and cooperation. AIMS To investigate feasibility, repeatability and reproducibility of measuring airway resistance using the interrupter technique (MicroRint) in people aged 50 years or over with a mild, moderate or severe intellectual disability. M...

متن کامل

Reference values of interrupter respiratory resistance in healthy preschool white children.

BACKGROUND Interrupter respiratory resistance (Rint) is reported to be useful in evaluating lung function in poorly collaborating patients. However, no reference values are available from large samples of preschool children using the standard interrupter method. The aim of this study was to define reference Rint values in a population of healthy preschool children. METHODS Rint was assessed w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 2003