Left atrial volume: comparison of 2D and 3D transthoracic echocardiography with ECG-gated CT angiography.
نویسندگان
چکیده
RATIONALE AND OBJECTIVES Left atrial volume (LAV) measurement by conventional two-dimensional (2D) transthoracic echocardiography (TTE) may be limited by the geometric model, by suboptimal definition of left atrial endocardium, or by chamber foreshortening. Three-dimensional (3D) TTE is posited to eliminate chamber foreshortening, and LAV measurement by 3D TTE should be more reflective of true LAV. The aim of this study was to compare conventional 2D TTE and newer 3D TTE for measurements of LAV to multidetector computed tomographic (MDCT) measurements using automated chamber reconstruction (ACR). MATERIALS AND METHODS Twenty-two subjects consented to undergo 2D TTE and 3D TTE immediately prior to or following coronary computed tomographic angiography. LAV was calculated from 2D TTE using the area-length method (ALM) and from 3D TTE with the ALM as well as with a 3D model. Electrocardiographically gated coronary computed tomographic angiography was performed in helical mode. LAV was measured using the ALM as well as ACR. RESULTS LAV was significantly smaller by 2D TTE (80 ± 21 mL) and 3D-TTE (90 ± 24 mL with the ALM, 61 ± 16 mL with the 3D model) compared to MDCT ACR (120 ± 30 mL) (P < .01). Correlation between MDCT ALM and MDCT ACR was excellent (mean Δ = -1.4 ± 14 mL, r = 0.91). Correlation with MDCT ACR was no better for 3D TTE (r = 0.80) than for 2D TTE (r = 0.80). CONCLUSIONS LAV is underestimated by both 2D TTE and 3D TTE relative to coronary computed tomographic angiography. Excellent agreement between the ALM and ACR with MDCT imaging suggests that the geometric model plays a negligible role in the underestimation of LAV. Underestimation of LAV by echocardiography is likely related to suboptimal definition of left atrial contour.
منابع مشابه
Head-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic Echocardiography
Results For the global EF, Bland-Altman analysis showed significantly higher agreement between CT and MRI (p 0.005, 95% confidence interval: 14.2%) than for CVG ( 20.2%) and 3D Echo ( 21.2%). Only CVG (59.5 13.9%, p 0.03) significantly overestimated EF in comparison with MRI (55.6 16.0%). CT showed significantly better agreement for stroke volume than 2D Echo, 3D Echo, and CVG. In comparison wi...
متن کامل'Coumadin ridge' in the left atrium demonstrated on three dimensional transthoracic echocardiography.
An echogenic band like structure was seen in the left atrium on two dimensional transthoracic echocardiography (2D TTE). Full volume three dimensional (3D) TTE and colour Doppler established the surrounding anatomical landmarks, and demonstrated the absence of obstruction related to this band. 3D TTE confirmed that this band like structure was consistent with the ridge between the left atrial a...
متن کاملLeft atrial volume assessed by transthoracic three dimensional echocardiography and magnetic resonance imaging: dynamic changes during the heart cycle in children.
OBJECTIVE To assess the dynamic changes in left atrial volume by transthoracic three dimensional echocardiography and compare the results with those obtained by magnetic resonance imaging (MRI). DESIGN AND PATIENTS 30 healthy children (15 boys and 15 girls, aged 8 to 13 years) underwent examination by three dimensional echocardiography and MRI. METHODS Three dimensional echocardiography of ...
متن کاملThree-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
BACKGROUND Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching arti...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Academic radiology
دوره 19 1 شماره
صفحات -
تاریخ انتشار 2012