Testing of Thin-Film Electrode Arrays for Cochlear Implants of the Future

نویسندگان

  • J. R Parker
  • Y. Y. Duan
چکیده

The Nucleus cochlear implant has been shown to give substantial communication benefit to the severe to profoundly deaf. Future cochlear implants will incorporate an advanced multi-channel electrode array, which will enable better sound-coding strategies to be implemented. This new electrode array will be fabricated using state-of-the-art micromachining technology. Any long-term implanted device such as a cochlear implant must undergo rigorous testing to ensure biological safety. In this paper four tests for the micromachined array are discussed. The tests are based on electrochemical methods, and include open circuit potential, galvanostatic biphasic pulse, 4-electrode shorting tests, and electrochemical impedance spectroscopy. This paper demonstrates that these test techniques arc effective and informative in the development of thin-film electrode arrays. They can be used to verify the fabrication steps, electrode quality, and the suitability for the biological environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robot Assisted Cochlear Implant Surgery

Cochlear implant surgery allows surgeons to restore partial hearing to patients suffering from severe hearing loss due to damaged neuroepithelial (hair) cells. During this surgery surgeons insert long, thin, and flimsy electrodes into the scala tympani inside cochlea. Our goal is to develop a robotic system to help surgeons achieve atraumatic cochlear implant surgery using novel steerable cochl...

متن کامل

Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article

The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...

متن کامل

High-density cochlear implants with position sensing and control.

Silicon-based thin-film technology has been used to develop high-density cochlear electrode arrays with up to 32 sites and four parallel channels of simultaneous stimulation. The lithographically-defined arrays utilize a silicon-dielectric-metal-parylene structure with 180 microm-diameter IrO sites on 250 microm centers. Eight on-board strain gauges allow real-time imaging of array shape during...

متن کامل

A strategy for degradation of 2,5-dichlorophenol using its photoelectrocatalytic oxidation on the TiO2/Ti thin film electrode

In this work, the photoelectrocatalytic (PEC) degradation of 2,5-dichlorophenol can be used for its removal from aqueous solution. To study this activity, a TiO2 thin film modified titanium sheet (TiO2/Ti) was fabricated by anodizing Ti plates using a two electrode system under the constant bias voltage of 20 V for 20 min in a solution of 0.2% (v/v) HF followed by calcinat...

متن کامل

Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion.

The level of hearing rehabilitation enjoyed by cochlear implant (CI) recipients has increased dramatically since the introduction of these devices. This improvement is the result of continual development of these systems and the inclusion of subjects with less severe auditory pathology. Developments include advanced signal processing, higher stimulation rates, greater numbers of channels, and m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009